Secondary Method:
Solder a Flat Braid (item 4, Figure 3-6) to the folded back shield on the prepared cable assembly
(item 2,
Figure 3-1
or
soldering practices. Use care to avoid applying excessive heat that burns through the insulation of the
center conductors and shorts the shield to the signal wire. Slide a minimum of 0.75 inches of Teflon
heat shrinkable tubing (item 3, Figure 3-6) onto the prepared wire assembly and shrink using a heat
gun. The chosen size of heat shrinkage tubing must accommodate both the number of conductors
present in the cable as well as the Flat Braid (item 4, Figure 3-6) to be attached.
Teflon Heat Shrinkable Tubing:
Reference the following MIL-Spec for general Teflon heat shrinkable tubing (M23053/5-X-Y)

Figure 3-6 Method B.1 (Quick Term) for Shield Termination

Table 3-7 Shielded Cable Preparations – (Quick Term)
Backshell Size
44 Pin
190-01879-11
Rev. 6
Figure
3-2). Ensure a solid electrical connection through the use of acceptable
Number of Pins
Quick Term Min
Std/HD
44
Quick Term Max
(inches)
(inches)
1.5
GMA 245/245R Installation Manual
Quick Term
Float (inches)
2.5
2.0
Page 3-12