Specifications and Reference Data
May 2017
Table A-2. Rosemount 3051P In-Line Pressure Transmitter Ordering Information
The starred offerings (
) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.
CN
Analog output levels compliant with NAMUR recommendation NE 43, low alarm
CR
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
CS
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
CT
Low alarm (standard Rosemount alarm and saturation levels)
Extended product warranty
WR3
3-year warranty
WR5
5-year warranty
HART revision configuration
(10)
HR5
Configured for HART Revision 5
(11)
HR7
Configured for HART Revision 7
Surface finish
Q16
Surface finish certification for sanitary remote seals
Toolkit total system performance reports
QZ
Remote seals system performance calculation report
Conduit electrical connection
GE
M12, 4-pin, male connector (eurofast
GM
A size mini, 4-pin, male connector (minifast
(12)
NACE certificate
Q15
Certificate of compliance to NACE
Q25
Certificate of compliance to NACE MR0103 for wetted materials
Stainless steel tagging
Y2
316SST Nameplates, Labels, Tags, and Fasteners
Typical model number:
1.
Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain
materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
2.
"Assemble-to" items are specified separately and require a completed model number.
3.
Panel mounting bolts are not supplied.
4.
Consult an Emerson Representative for availability of Product Certifications.
5.
Not available with assemble-to manifold (S5 code), assemble-to seal (S1 code), surface finish certification (Q16 code), remote seal system report (QZ code).
6.
Not valid with alternate process connection S5.
7.
Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
8.
The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
9.
Select Configuration Buttons (option code D4 or DZ) if local configuration buttons are required.
10. Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
77
®
)
®
®
MR0175/ISO 15156 for wetted materials
3051P P 5 F 2A 2 1 A HR5 B4
)
Reference Manual
00809-0700-4001, Rev AA
Specifications and Reference Data

Advertisement

Table of Contents
loading

Table of Contents