SUMMARY OF AUDIBLE/VISUAL NOTIFICATIONS
SOUND
CAUSE
LOUD, INTERRUPTED*
FIRE ALARM
Keypad & External Sounder
LOUD, CONTINUOUS*
BURGLARY/AUDIBLE
Keypad &External Sounder
EMERGENCY ALARM
ONE SHORT BEEP
a. SYSTEM DISARM
(not repeated)
b. SYSTEM ARMING ATTEMPT
Keypad only
WITH AN OPEN ZONE
c. BYPASS VERIFY
ONE SHORT BEEP
SYSTEM IS IN TEST MODE
(once every 40 seconds)
Keypad only
ONE BEEP every 40 sec.
a. LOW BATTERY AT XMTR
Keypad only
b. SYST. MAIN BATT. WEAK
c. TROUBLE
TWO SHORT BEEPS
ARM AWAY OR MAXIMUM
Keypad only
THREE SHORT BEEPS
a. ARM STAY OR INSTANT
Keypad only
b. ZONE OPENED WHILE SYS-
TEM IS IN CHIME MODE
c. ZONE OPENED WHILE SYS-
TEM IS IN TEST MODE
RAPID BEEPING
MEMORY OF ALARM
Keypad only
SLOW BEEPING
a. ENTRY DELAY WARNING
Keypad only
b. EXIT DELAY ALERT
(if programmed)
*If bell is used as external sounder, fire alarm is pulsed ring (see page 29); burglary/audible emergency is steady ring.
Note: Also see Other Trouble Displays and Total Power Failure under TROUBLE CONDITIONS on pages 27 and 28.

(FIXED-WORD DISPLAY KEYPADS)

DISPLAY
FIRE and ALARM are displayed; protection zone in alarm is displayed.
ALARM is displayed; protection zone in alarm is also displayed.
Also see "Exit Alarm Warning Displays and Sounds" on page 21.
a. Only READY is displayed. Green READY indicator (if present) is lit.
b. NOT READY is displayed, open protection zone number is displayed.
Green READY indicator (if present) is not lit.
c. The bypassed protection zone numbers are displayed. (One beep for each number
displayed.) BYPASS displayed.
Opened Zone identifications will appear.
a. BAT displayed with ID number of transmitter.
b. BAT displayed with no transmitter ID
c. CHECK displayed. Troubled protection zone is displayed.
AWAY and (if MAXIMUM) INSTANT are displayed.
a. STAY and (if INSTANT) INSTANT are displayed. Red ARMED indicator is lit.
b. CHIME displayed. Pressing READY [ ] key will display opened zone.
c. Open protection zone number is displayed.
FIRE and/or ALARM is displayed; zone in alarm is displayed.
a. No display during delay; Exceeding the delay time without disarming causes alarm.
b. AWAY or (if MAXIMUM) AWAY INSTANT is displayed. Slow beeps change to fast beeps
during last 5 seconds of exit delay.