Emerson Fisher 4200 Instruction Manual page 4

Electronic position
Table of Contents

Advertisement

4200 Transmitters
March 2011
Table 2. Available Configurations
TYPE
TRANSMITTER
NUMBER
4210
4211
4212
- - -
4215
4220
4221
4222
- - -
1. See table 3 for zero and span limits.
Table 3. Zero and Span Limits
DEGREES OF
POTENTIOMETER ROTATION
TYPE
NUMBER
Zero
Position
4210
4211
0 to 90
4212
4215
4220
0 to 884
4221
4222
1. Zero position is the range of values over which the transmitter zero can be adjusted. Span is the range of shaft rotation or stem travel the transmitter span can be adjusted. For example, a
zero position of 45 degrees and a span of 15 degrees means the transmitter output is 4 mA DC after 45 degrees of shaft rotation. The output then increases from 4 mA DC to 20 mA DC as the
shaft rotates from 45 to 60 degrees.
2. Refer to figures 15, 22, and 23 for locations of connections.
Figure 3. Power Supply Requirements
1000
750
650
500
250
0
0
10
11
POWER SUPPLY VOLTAGE (VOLTS DC)
A6765/IL
4
ELECTRICAL
POSITION
SWITCHES
X
X
X
- - -
X
X
X
X
X
X
- - -
X
(1)
CONNECTION
Span
Min.
Max.
15
90
12‐Inch Transducer
150
884
24‐Inch Transducer
OPERATING
REGION
20
30
MAXIMUM TRANSMITTER TERMINAL VOLTAGE
24
NOMINAL SUPPLY VOLTAGE
MINIMUM TRANSMITTER TERMINAL VOLTAGE
TRAVEL
Standard Stroke
(1)
Up to 105 mm
(Up to 4.125 Inches)
X
X
X
X
- - -
- - -
- - -
mm
(2)
Zero
Position
1
0 to 51
2
0 to 105
0 to 305
0 to 610
Instruction Manual
Long‐Stroke
(1)
Up to 610 mm
(Up to 24 Inches)
- - -
- - -
- - -
- - -
X
X
X
SLIDING‐STEM ACTUATOR TRAVEL
Span
Zero
Position
Min.
Max.
8
51
0 to 2
17
105
0 to 4.125
105
305
0 to 12
305
610
0 to 24
D200354X012
DUAL
POTENTIOMETER
- - -
- - -
- - -
X
- - -
- - -
- - -
INCHES
Span
Min.
Max.
0.315
2
0.670
4.125
4.125
12
12
24