Recovering Management And Control Connectivity Of A Host When A Vsm Is Running On A Vem; Using The Vem Connect Script - Cisco Nexus 1000V Troubleshooting Manual

Hide thumbs Also See for Nexus 1000V:
Table of Contents

Advertisement

Problems with the VSM
S e n d d o c u m e n t c o m m e n t s t o n e x u s 1 k - d o c f e e d b a c k @ c i s c o . c o m .
vlan
------+----------------+--------+-----+----------+--------------------------
Active Supervisor:
* 3002
Do one of the following:
Step 6
Step 7
On the VEM, enter the following commands to verify that the VSM MAC appears in the control and
packet VLANs.
config t
module vem module_number execute vemcmd show l2 control_vlan_id
module vem module_number execute vemcmd show l2 packet_vlan_id
The VSM eth0 and eth1 MAC addresses should display in the host control and packet VLANs.
Example:
n100v# config t
n1000v(config)# module vem 3 execute vemcmd show l2 3002
Bridge domain 3002 brtmax 100, brtcnt 3, timeout 120
n1000v(config)# module vem 3 execute vemcmd show l2 3003
Bridge domain 3002 brtmax 100, brtcnt 3, timeout 120
Do one of the following:
Step 8
Recovering Management and Control Connectivity of a Host when a VSM is
Running on a VEM
When the VSM is running on a VEM that it manages, but the VSM ports are not configured with system
port profiles, the control and management connectivity of the VSM can be lost after a host reboot or
similar event. To recover from the loss, you can run the VEM connect script locally in the ESX host
where the VEM is running. Then go to the VSM and configure the system VLANs in the port profile
used for management.

Using the VEM Connect Script

The VEM connect script sets a given VLAN as a system VLAN on the vmknic that has the given IP
address, and also sets the VLAN on all the required uplinks.
Cisco Nexus 1000V Troubleshooting Guide, Release 4.2(1)SV2(2.1)
7-12
mac address
type
00:02:3d:40:0b:0c
If the output from
Step 5
does not display the MAC address of the VSM, then there is a problem
with connectivity between the server hosting the VSM and the upstream switch. Recheck the VSM
configuration and vCenter Server configuration.
Otherwise, continue with the next step.
Dynamic MAC 00:50:56:be:7c:a7
Dynamic MAC 00:02:3d:40:0b:0c
Dynamic MAC 00:50:56:be:7c:a7
Dynamic MAC 00:02:3d:20:0b:0c
If the MAC address of the VSM does not appear in the output of
configuration as explained in
Otherwise, you have completed this procedure.
learn
age
dynamic
Yes
0
LTL
16 pvlan
LTL
10 pvlan
LTL
16 pvlan
LTL
10 pvlan
"Checking the VEM Configuration" section on page
Chapter 7
VSM and VEM Modules
ports
Gi3/2
0 timeout
110
0 timeout
110
0 timeout
110
0 timeout
110
Step
7, then check the VEM
7-14.
OL-28795-01

Advertisement

Table of Contents
loading

Table of Contents