Chapter 7
VSM and VEM Modules
S e n d d o c u m e n t c o m m e n t s t o n e x u s 1 k - d o c f e e d b a c k @ c i s c o . c o m .
Example:
n1000v# show svs connections
connection vc:
Do one of the following:
Step 7
•
•
Verifying the VSM Is Configured Correctly
This section includes the following procedures to verify the VSM configuration.
•
•
•
Verifying the Domain Configuration
You can use the following procedure to verify the domain configuration.
BEFORE YOU BEGIN
Before beginning this procedure, you should know or do the following:
•
•
On the VSM, verify the domain configuration.
Step 1
show svs domain
Example:
n1000v# show svs domain
SVS domain config:
Domain id:
Control vlan: 3002
Packet vlan:
L2/L3 Control VLAN mode: L2
L2/L3 Control VLAN interface: mgmt0
Status: Config push to VC successful
OL-28795-01
ip address: 172.23.231.223
protocol: vmware-vim https
certificate: user-installed
datacenter name: hamilton-dc
DVS uuid: 92 7a 14 50 05 11 15 9c-1a b0 f2 d4 8a d7 6e 6c
config status: Disabled
operational status: Disconnected
If the status is Connected, then you have completed this procedure.
If not, then return to the
Flowchart: Troubleshooting Modules, page
Verifying the Domain Configuration, page 7-7
Verifying the System Port Profile Configuration, page 7-8
Verifying the Control and Packet VLAN Configuration, page 7-8
You are logged in to the CLI in EXEC mode.
The output of the show svs domain command should indicate the following:
–
The presence of a control VLAN and a packet VLAN.
–
The domain configuration was successfully pushed to VC.
682
3003
Cisco Nexus 1000V Troubleshooting Guide, Release 4.2(1)SV2(2.1)
Problems with the VSM
7-3.
7-7