Verifying the VSM Is Configured Correctly

This section includes the following procedures to verify the VSM configuration.

Verifying the Domain Configuration

You can use the following procedure to verify the domain configuration.
BEFORE YOU BEGIN
Before beginning this procedure, you should know or do the following:
On the VSM, verify the domain configuration.
Step 1
show svs domain
Example:
n1000v# show svs domain
SVS domain config:
Domain id:
Control vlan: 3002
Packet vlan:
L2/L3 Control VLAN mode: L2
L2/L3 Control VLAN interface: mgmt0
Status: Config push to VC successful
OL-28795-01
ip address: 172.23.231.223
protocol: vmware-vim https
certificate: user-installed
datacenter name: hamilton-dc
DVS uuid: 92 7a 14 50 05 11 15 9c-1a b0 f2 d4 8a d7 6e 6c
config status: Disabled
operational status: Disconnected
If the status is Connected, then you have completed this procedure.
If not, then return to the
Flowchart: Troubleshooting Modules, page
Verifying the Domain Configuration, page 7-7
Verifying the System Port Profile Configuration, page 7-8
Verifying the Control and Packet VLAN Configuration, page 7-8
You are logged in to the CLI in EXEC mode.
The output of the show svs domain command should indicate the following:
The presence of a control VLAN and a packet VLAN.
The domain configuration was successfully pushed to VC.