Grandstream Networks UCM6200 Series User Manual page 149

Ip pbx
Hide thumbs Also See for UCM6200 Series:
Table of Contents

Advertisement

Tone Settings
Busy Detection
Busy Tone Count
Congestion Detection
Congestion Count
Tone Country
Busy Tone
Congestion Tone
Firmware Version 1.0.0.1
When the call goes out from this analog trunk, it will always try to use
the last idle FXO port. The port order that the call will use to go out
would be port 16->port 10->port 2->port 1. Every time it will start with
port 16 (if it's idle).
The default setting is "Ascend" mode.
Busy Detection is used to detect far end hangup or for detecting busy
signal. The default setting is "Yes".
If "Busy Detection" is enabled, users can specify the number of busy
tones to be played before hanging up. The default setting is 2. Better
results might be achieved if set to 4, 6 or even 8. Please note that the
higher the number is, the more time is needed to hangup the channel.
However, this might lower the probability to get random hangup.
Congestion detection is used to detect far end congestion signal. The
default setting is "Yes".
If "Congestion Detection" is enabled, users can specify the number of
congestion tones to wait for. The default setting is 2.
Select the country for tone settings. If "Custom" is selected, users could
manually configure the values for Busy Tone and Congestion Tone. The
default setting is "United States of America (USA)".
Syntax:
f1=val[@level][,f2=val[@level]],c=on1/off1[-on2/off2[-on3/off3]];
Frequencies are in Hz and cadence on and off are in ms.
Frequencies Range: [0, 4000)
Busy Level Range: (-300, 0)
Cadence Range: [0, 16383].
Select Tone Country "Custom" to manually configure Busy Tone value.
Default value:
f1=480@-50,f2=620@-50,c=500/500
Syntax:
f1=val[@level][,f2=val[@level]],c=on1/off1[-on2/off2[-on3/off3]];
Frequencies are in Hz and cadence on and off are in ms.
Frequencies Range: [0, 4000)
Busy Level Range: (-300, 0)
Cadence Range: [0, 16383].
Select Tone Country "Custom" to manually configure Busy Tone value.
Default value:
f1=480@-50,f2=620@-50,c=250/250