Product Specific Information

A. Appliance Certification
MODEL:
Quadra-Fire Hudson Bay
LABORATORY:
OMNI Test Laboratories, Inc.
REPORT #
0061GS029S
TYPE:
Direct Vent Gas Heater
ANSI Z21.88-2014, CSA 2.33-2014,
STANDARD:
CAN/CSA 2.17-M91 (R2009)
The product is listed to ANSI standards for "Vented Gas
Appliance Heaters" and applicable sections of "Gas
Burning Heating Appliances for Manufactured Homes and
Recreational Vehicles" and "Gas Fired Appliances for use
at High Altitudes".
Manufactured Home or Mobile Home installation may
occur only after the home is site located and must conform
with the Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280, or, when such a
standard is not applicable, the Standard for Manufactured
Home Installations, ANSI/NCSBCS A225.1, or Standard for
Gas Equipped Recreational Vehicles and Mobile Housing,
CSA Z240.4.
When installed, the appliance must be electrically grounded
in accordance with local codes or, in the absence of local
codes, with the National Electrical Code, ANSI/NFPA 70, or
the Canadian Electrical Code, CSA C22.1.
B. Glass Specifications
This appliance is equipped with 5mm ceramic glass.
Replace glass only with 5mm ceramic glass. Please contact
your dealer for replacement glass.
Installation and service of this appliance should be performed by
qualified personnel. Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
NOTE: This installation must conform with local
codes. In the absence of local codes you must
comply with the National Fuel Gas Code, ANSI
Z223.1-latest edition in the U.S.A. and the
CAN/CGA B149 Installation Codes in Canada.
!
Do NOT use this appliance if any part has been under
water. Immediately call a qualified service technician
to inspect the unit and to replace any part of the control
system and any gas control which has been under
water.
6
WARNING
Quadra-Fire • Hudson Bay • 3-90-7003998_R25 • 07/17
C. BTU Specifications
Maximum
Minimum
Model
Input
(US or Canada)
BTU
Hudson Bay
42,000
28,000
(NG)
Hudson Bay
40,500
31,000
(LP)
* Thermal efficiency maximum pipe with blower on.
** Canada minimum pipe.
Orifice
Input
Size
*Steady State
BTU
(DMS)
Efficiency %
.125
84.02
.076
85.71
**P.4 %
64.03
65.43