Product Specific and Important Safety Information

A. Appliance Certification
MODELS: QFI30FB-IFT, QFI35FB-IFT
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Heater
STANDARD: ANSI Z21.88-2017 • CSA 2.33-2017
This product is listed to ANSI standards for "Vented Gas
Fireplace Heaters" and applicable sections of "Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles", and "Gas Fired Appliances for
Use at High Altitudes".
Quadra-Fire gas inserts are designed for installations into
solid fuel masonry or factory built fireplaces that have been
installed in accordance with the National, Provincial, State
and local building codes. Fireplaces are to be constructed
of non-combustible materials and, in the absence of local
or regional codes, meet criteria of NFPA 211. No additional
outside air source is required.
NOTICE: This installation must conform with local codes.
In the absence of local codes you must comply with the
National Fuel Gas Code, ANSI Z223.1-latest edition in
the U.S.A. and the CAN/CGA B149 Installation Codes in
Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemen-
tal room heat or as a decorative appliance. It should not be
factored as primary heat in residential heating calculations.
B. Glass Specifications
This appliance is equipped with 5 mm ceramic glass with
an anit-reflective coating. Replace glass only with 5 mm
ceramic glass. Please contact your dealer for replace-
ment glass.
C. BTU Specifications
Models
(U.S. or Canada)
QFI30FB-IFT
(0-2000 FT)
(NG)
QFI30FB-IFT
(0-2000 FT)
(Propane)
QFI35FB-IFT
(0-2000 FT)
(NG)
QFI35FB-IFT
(0-2000 FT))
(Propane)
4
Maximum
Minimum
Input
Input
BTU/h
BTU/h
36,000
18,500
36,000
19,000
40,000
20,000
38,000
19,000
Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18
D. High Altitude Installations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 feet elevation:
• In the USA: Reduce input rate 4% for each 1000 feet
above 2000 feet.
• In CANADA: Input ratings are certified without a
reduction of input rate for elevations up to 4500 feet
(1370 m) above sea level. Please consult provincial
and/or local authorities having jurisdiction for
installations at elevations above 4500 feet (1370 m).
Check with your local gas utility to determine proper
orifice size.
E. Non-Combustible Materials Specification
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in
a Vertical Tube Furnace at 750 ºC shall be considered
non-combustible materials.
F. Combustible Materials Specification
Materials made of or surfaced with wood, compressed pa-
per, plant fibers, plastics, or other material that can ignite
and burn, whether flame proofed or not, or plastered or
unplastered shall be considered combustible materials.
G. Electrical Codes
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• A 110-120 VAC circuit for this product must be pro-
tected with ground-fault circuit-interrupter protection,
Orifice
in compliance with the applicable electrical codes,
Size
when it is installed in locations such as in bathrooms
(DMS)
or near sinks.
33
H. California
50
WARNING: This product and the fuels used to
operate this product (liquid propane or natural
31
gas), and the products of combustion of such fuels, can
expose you to chemicals including benzene, which is
49
known to the State of California to cause cancer and
reproductive harm. For more information go to: www.
P65Warnings.ca.gov.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qfi35fb-ift

Table of Contents