Overview; Safety Messages; Warnings; Section 2 Overview - Emerson Rosemount 3051S Series Reference Manual

Scalable pressure, flow, and level solution with hart protocol
Hide thumbs Also See for Rosemount 3051S Series:
Table of Contents

Advertisement

Reference Manual
00809-0100-4801, Rev EA
August 2010
Section 2

OVERVIEW

SAFETY MESSAGES

Warnings

Installation
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1
Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-1
Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-2
Installation Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2-5
Installing the LCD Display . . . . . . . . . . . . . . . . . . . . . . . . . page 2-21
Rosemount 305, 306 and 304 Manifolds . . . . . . . . . . . . . . page 2-22
The information in this section covers installation considerations for HART
protocol. A Quick Installation Guide for HART protocol (document number
00825-0100-4801) is shipped with every transmitter to describe basic
installation, wiring, and startup procedures. Dimensional drawings for each
Rosemount 3051S variation and mounting configuration are included in
Appendix A: Specifications and Reference Data.
Instructions for performing configuration functions are given for Field
Communicator version 3.3 and AMS version 7.0, with the exception of
Section 7 Advanced HART Diagnostics. For convenience, Field
Communicator fast key sequences are labeled "Fast Keys" for each software
function below the appropriate headings.
Procedures and instructions in this section may require special precautions to
ensure the safety of the personnel performing the operation. Information that
raises potential safety issues is indicated with a warning symbol (
to the following safety messages before performing an operation preceded by
this symbol.
Explosions can result in death or serious injury.
• Do not remove the transmitter covers in explosive environments when the
circuit is live.
• Fully engage both transmitter covers to meet explosion-proof requirements.
• Before connecting a communicator in an explosive atmosphere, make sure the
instruments in the loop are installed in accordance with intrinsically safe or
non-incendive field wiring practices.
• Verify that the operating atmosphere of the transmitter is consistent with the
appropriate hazardous locations certifications.