1.2.2

Power Supply

(1) Power supply
(2) Battery type
(3) Service life of batteries
(4) Automatic powering-off
(5) Low battery detection and indication
Indicated on LCD
Assurance limit for the printing quality (Stop after printing)
- When the machine is driven by batteries: Low Battery!
Limit for printing (Stop even in the middle of printing)
- When the machine is driven by batteries: Replace Battery!
Cut OFF: Turns the power OFF forcefully or does not turn ON the power.
Driven by:
Alkaline batteries (LR6) x6,
Ni-MH batteries (HR6) x6
Specified AC adapter available: AD-E001 **
("**" part changes depending on US, EU, and UK.)
Alkaline batteries (LR6)/Ni-MH batteries (HR6)
that come with the machine.
Will last through one 24-mm wide tape cassette,
and then some (at room temperature and
normal humidity).
Dry cell battery
5 minutes
When using P-touch labeler only.
When connected to a PC, 1 hour.
Adapter
8 hours
I - 5