CHARGING SYSTEM
A. C generator
INSPECTION
CHARGING OUTPUT CHECK
Start the engine and keep it running at 5,000 rpm.
Using the pocket tester, measure the DC voltage
between the battery terminal
If the voltage is not within the specified value, check
the magneto no-load performance and regulator /
rectifier.
CAUTION
When making this test, be sure that the battery is
full-charged condition.
Standard charge
Tester knob indication : Voltage (
Regulator / Rectifier
and
.
13.5
15.0 V
(at 5,000 rpm)
)
91
91
ELECTRICAL SYSTEM 5-7
Ignition switch
IC
Regulator
/
Rectifier
Battery
Ignition switch
DCV