Connecting remote controllers, cameras, and setup PC using LAN connection
Connection example
MODE
LAN
RS-232C
RS-422
VISCA
RM-IP10
Setup PC
Remote control signal: LAN cable (category 5 or higher)
Tally/contact signal: Connection cable with D-sub 15-pin connectors
Video signal: HDMI cable
Video signal: Connection cable with BNC connectors
Signal flow
*1 For an example connection with a video switcher, see "Connection with a video switcher" (page 24).
*2 Use a connection cable designed for the switcher being used. For the specifications of the GPI I/O connector of
the unit, see "Pin assignments" (page 52).
*3 To connect the BRC-H900 using a LAN connection, a BRBK-IP10 IP control card must be installed. In addition,
use an IP control card with firmware version 2.1 or later.
1
Connect the LAN connector of the units and LAN
connector of the cameras using LAN cables.
You can connect up to 100 cameras and five remote
controllers on the same network.
2
To configure setting of the unit and cameras using
setup software, connect a PC to the same network.
• Use shielded-type LAN cables to prevent
malfunction that may result from radiation noise.
• Use a LAN cable (category 5 or higher).
RM-IP500
BRBK-IP10 IP
control card
!
Switching hub
Video monitor
*2
BRC-H900
1 2 3
1 2 3 4 5 6 7 8 9
IR SELECT
VISCA RS-422
OFF
ON
HD
SD
RGB/COMPONENT
75
IN VISCA RS-232 OUT
EXT SYNC IN
VIDEO
S VIDEO
SDI OUT
1
2
DATA MIX
BRBK-IP10
OFF
ON
HD
SD
LAN
SDI OUT
*3
BRC-X1000,
BRC-H800
IR SELECT
CAMERA SETUP
1 2 3
SYSTEM
IN
VISCA RS - 422 OUT
LAN
SELECT
OSD
ON OFF
HDMI OUT
MONITOR OUT
LINE OUT
EXT SYNC IN
SDI 1
SDI 2
SDI 1
SDI 2
SRG-360SHE
RAUD RATE
MIC
VISCA RS-422
R
L
(PLUG IN POWER)
SYSTEM
SELECT
HDMI OUT
SDI OUT
• Connect the cameras, remote controllers, and PC
via switching hubs (10BASE-T or 100BASE-
TX). Use on a network with significant packet
loss or delay may cause a malfunction. Use a
high-quality network.
• Do not mix 10BASE-T and 100BASE-TX in the
network.
• The IP address of the unit is set to 192.168.0.10,
and the IP address of a camera and BRBK-IP10