MAINTENANCE

Removing and Installing the Earpiece

Recommended tools: tweezers.

To remove the Earpiece from the unit

(See Figure 22 on page 6-30, item No. 9)
1. Remove the Rotary Switch from the unit. Refer to "Removing and Installing
2. Using the tweezers grasp the earpiece and with an upward motion remove

To install the Earpiece

1. Be sure to place the earpiece correctly (evenly) into the rubber boot with the
2. Gently push the earpiece into the boot until it is firmly inside the boot.
3. Install the Rotary Switch.
Removing and Installing the UC Escutcheon (applicable to MTP850
S and MTP850 FuG only)
Recommended tools: Tweezers or narrow blade knife.

To remove the UC Escutcheon from the unit

1. Carefully insert the tweezers or knife inside the escutcheon.
2. Using the tweezers or knife, gently pry the UC Escutcheon away from the
3. Remove any remains of the adhesive.

To install the UC Escutcheon

1. Align the UC Escutcheon appropriately to the front housing by using the UC
2. Press the UC Escutcheon into the Front Housing until it fits in place.
MTP850 TETRA Handportable Terminal / Basic Service Manual
the Rotary Switch" on page 6-24.
the earpiece.
spring contacts pointing in the upward direction. Use tweezers for this
operation.
front housing. Careful handling is required to avoid causing cosmetic defects
to the surrounding components.
Escutcheon slot as a guide.