Manuals and User Guides for Motorola IRRInet-XL. We have
1
Motorola IRRInet-XL manual available for free PDF download: Owner's Manual
Motorola IRRInet-XL Owner's Manual (100 pages)
Remote Terminal Unit
Brand:
Motorola
| Category:
Touch terminals
| Size: 4.04 MB
Table of Contents
Table of Contents
2
Chapter 1 General Description
11
Irrinet-XL - RTU Wall Mount and Housing Options
11
Figure 1-1 3-Slot Chassis Wall Mount Style
11
Figure 1-2 NEMA4X Plastic Housing Style - Mobile Radios
11
Figure 1-3 NEMA4X Plastic Housing Style - Portable Radio
12
Figure 1-4 NEMA4 Housing Style - Portable
12
Figure 1-5 External Radio Ready Setup
13
RTU Models
14
Table 1-1 RTU Models
14
I/O & Communication Modules
15
Table 1-2 I/O & Communication Modules
15
Power Supply and Backup Battery Options
16
Table 1-3 Power Supplies and Backup Battery Options
16
Chapter 2 Installation
17
Before Mounting the RTU
17
Figure 2-1 no Double Insulation Sign
17
Wall Mounting of RTU Without Housing Enclosure
18
Figure 2-2 RTU 3-Slot Chassis Installation Dimensions
18
Wall Mounting of RTU in NEMA4X Housing Enclosure
19
Figure 2-3 NEMA4X Plastic Housing - Installation Dimensions
19
Wall Mounting of RTU with NEMA4 Housing Enclosure
20
Figure 2-4 NEMA4X Plastic Housing - Mounting Brackets Installation
20
Figure 2-5 Installation of NEMA4 Housing
20
Electrical Connections
21
Ground Connection
21
Figure 2-6 Irrinet-XL Grounding Strips
21
Main Power Connections
22
Figure 2-7 External DC Power Source Connections - Using Mobile Radios on Wall Mount or NEMA4X
22
Figure 2-8 External DC Power Source Connections - Using Portable Radio on Wall Mount or NEMA4X
23
Electrical Connections for 8 Ampere Power Supply
24
Figure 2-9 External DC Power Source Connections - Using Portable Radio in NEMA4 Housing
24
Figure 2-10 8 Ampere Power Supply 115VAC or 230 VAC - TB Layout
25
Figure 2-11 8 Ampere Power Supply Front Panel
26
Table 2-1 8 Ampere Power Supply - Front Panel Controls, Indicators, and Connectors
26
Ampere Power Supply Field Replaceable Parts
27
Electrical Connections for 45 VA Power Transformer
27
Table 2-2 8 Ampere Power Supply Field Replaceable Parts
27
Figure 2-12 Connecting the 45 VA Transformer on 3-Slot Chassis or NEMA4X Housing Enclosure
29
VA Transformer Field Replaceable Parts
30
Backup Battery Connections
30
5AH Backup Battery
30
Figure 2-13 Connecting the 45 VA Transformer in NEMA4 Housing Enclosure
30
Table 2-3 45 VA Transformer Field Replaceable Parts
30
5AH Backup Battery Field Replaceable Parts
31
Figure 2-14 5AH Backup Battery Connection
31
Table 2-4 5AH Backup Battery Field Replaceable Parts
31
3AH Backup Battery
32
3AH Backup Battery Field Replaceable Parts
32
Figure 2-15 3AH Backup Battery Connection
32
Table 2-5 3AH Backup Battery Field Replaceable Parts
32
Radio Connections
33
Mobile Radio
33
Figure 2-16 NEMA4X Plastic Housing Style with Mobile Radios
33
Mobile Radio Field Replaceable Parts
34
Table 2-6 Mobile Radio Field Replaceable Parts
34
Portable Radios
35
Figure 2-17 NEMA4X Plastic Housing Style with Portable Radio
35
Figure 2-18 NEMA4 Housing Style with Portable Radio
35
Portable Radio Field Replaceable Parts
37
Table 2-7 Portable Radio Field Replaceable Parts
37
RTU Configuration Block Diagrams
38
Basic Interconnection Block Diagram
38
Figure 2-19 RTU in NEMA4 Housing - Basic Interconnection Diagram
38
Connecting the RTU by Wire Line
39
Figure 2-20 Connecting the RTU by Wire Line - Interconnection Diagram
39
Connecting the RTU by Single Mobile Radio
40
Figure 2-21 Connecting the RTU by Single Mobile Radio - Interconnection Diagram
40
Connecting the RTU by Two Separate Mobile Radios
41
Figure 2-22 Connecting the RTU by Two Separate Mobile Radios - Interconnection Diagram
41
Installation of Plug-In Modules and Units
42
Module Replacement
43
Removing the Power Supply Module
43
Installing the Power Supply Module
43
Radio Antenna Placement
44
Irrinet-XL Field Replaceable Parts
45
Table 2-8 Irrinet-XL Field Replaceable Parts
45
Chapter 3 In-Box Modules
46
Power Supply Module
46
Power Supply Versions
46
Powering the Module
46
Front Panel - Controls, Indicators and Connectors
47
Figure 3-1 Power Supply Module - Front Panel
47
Power Supply Module Field Replaceable Parts
48
Table 3-1 Power Supply Module Field Replaceable Parts
48
CPU Module
49
Figure 3-2 CPU Module - Front Panel
49
Front Panel Display Controls and Connectors
50
LED Display
50
Front Panel Controls
50
Figure 3-3 CPU LED Display
50
Table 3-2 CPU Matrix Display - LED Status Indications
51
Software Downloading
53
Connectors
53
CPU Module Field Replaceable Parts
53
Table 3-3 CPU Module Field Replaceable Parts
53
I/O-AC Module
54
Figure 3-4 I/O-AC Module - General View
54
Wire Connections
55
Figure 3-5 I/O-AC Module - External 75 VA Transformer User Connections
56
Figure 3-6 I/O-AC Module - I/O User Connections
57
Diagnostic LED Panel
58
Figure 3-7 I/O-AC Module LED Display
58
Table 3-4 I/O-AC Module Indication Display
58
I/O-AC Module Field Replaceable Parts
59
Table 3-5 I/O-AC Module Field Replaceable Parts
59
I/O-DC Module
60
Figure 3-8 I/O-DC Module - General View
60
Figure 3-9 I/O-DC Module - User Connections
61
Wire Connections
61
Diagnostic LED Panel
62
Figure 3-10 I/O DC Module LED Display
62
Table 3-6 I/O-DC Module Diagnostic Led Display
62
I/O-DC Module Field Replaceable Parts
63
Table 3-7 I/O-DC Module Field Replaceable Parts
63
Single Cable Module
64
Figure 3-11 Single Cable Module - General View
64
Wire Connections
65
Figure 3-12 Single Cable Module - User Connections
66
Diagnostic LED Panel
67
Figure 3-13 Single Cable Module LED Display
67
Table 3-8 Single Cable Module - Diagnostic Led Display
67
Single Cable Module Field Replaceable Parts
69
Table 3-9 Single Cable Module Field Replaceable Parts
69
Chapter 4 In-Box Communication Units
70
Communication Management Unit (CMU)
70
Figure 4-1 CMU Module - General View
70
Figure 4-2 CMU Module - Port 2 & Port 3 with 2 Mobile Radios User Connections
71
Wire Connections
71
Figure 4-3 CMU Unit and Single Mobile Radio - User Connections
72
Figure 4-4 CMU Module - Port 2 Wire Line User Connections
73
Diagnostic LED Panel
75
Removal and Installation
75
Setting the LED Display to the Relevant Module
75
CMU Unit Field Replaceable Parts
76
Table 4-2 CMU Diagnostic Led Display
76
Table 4-3 CMU Unit Field Replaceable Parts
76
Line Interface Units
77
Line Interface Options
77
Table 4-4 Line Interface Unit - Connection Types
77
Installation
78
Wire Connections
78
Figure 4-5 Line Interface Unit - Installation Location
78
Figure 4-6 Telephone Line Option - Electrical Connections
79
Figure 4-7 Multi-Drop Option - Electrical Connections
80
Figure 4-8 2W Leased Line Option - Electrical Connections
81
Figure 4-9 4W Leased Line Option - Electrical Connections
82
Figure 4-10 Typical 4-Wire Line Modem Interconnection
82
Removal and Installation
83
Diagnostic Led's
83
Line Interface Unit Field Replaceable Parts
84
Table 4-5 Line Interface Unit Field Replaceable Parts
84
Connection Board
85
Installation
85
Wire Connections
85
Figure 4-11 RS-485 Connection Board - Installation Location
85
Removal and Installation
86
Chapter 5 Cables and Adapters
87
RTU-To-Computer / Terminal Connections
87
Figure 5-1 RJ45-To-D-Type Female Connector Adapter
88
RTU to Modem Connection
89
RTU-To-Modem Asynchronous Connection
89
Figure 5-2 RJ45-To-D-Type Male Connector Adaptor
89
Table 5-1 RTU to Modem Asynchronous Connection
89
RTU-To-Modem Synchronous Connection (DTE-To-DCE)
90
Figure 5-3 RJ45-To-D-Type Male Connector Adaptor
90
Table 5-2 RTU-To-Modem Synchronous Connection (DTE-To-DCE)
90
RTU-To-RTU Connections
91
RTU-To-Multiple Rtus Time Synchronization Using SYNCH Broadcast (Via Port 1B)
91
RTU-To-RTU Asynchronous Communications Connection
91
Figure 5-4 Time Synchronization Using SYNCH Broadcast - Interconnection Diagram
91
Figure 5-5 RTU-To-RTU RS-232 Asynchronous Communications Cable
92
Figure 5-6 RTU-To-RTU Synchronous Communications Cable
93
Connecting a User Port to a Printer
94
Figure 5-7 RTU-To-RTU Synchronous Communications Cable
94
VA Transformer to Power Supply Cable FKN4463
95
Solar Panel to Power Supply Module Cable FKN4469
95
Figure 5-8 Transformer to Power Supply Cable FKN4463A
95
Figure 5-9 Solar Panel to Power Supply Module Cable FKN4469
95
Chapter 6 Cable Suppression Cores
96
Figure 6-1 I/O and CPU Port 3 Cable Suppression Cores - User Connections
96
Cable Suppression Cores Field Replaceable Parts
97
Figure 6-2 CPU Port 2 Cable Suppression Core - User Connection
97
Table 6-1 Cable Suppression Cores Field Replaceable Parts
97
Chapter 7 DC Line Filter Assembly Instructions
98
Usage Consideration
98
Figure 7-1 DC Line Filter - User Connections
98
Assembly Instructions
99
DC Line Filter Field Replaceable Parts
99
Table 7-1 DC Line Filter Field Replaceable Parts
99
Chapter 8 Cpu Ram Backup Battery
100
Figure 8-1 CPU RAM Backup Battery - User Connections
100
Advertisement
Advertisement
Related Products
Motorola IRRInet-M DC
Motorola IRON MAX
Motorola i605
Motorola i60c
Motorola i885
Motorola IDEN I833BABYPHAT
Motorola i856w - Boost Mobile Debut
Motorola IT6-2
Motorola iDEN i305
Motorola StarTac II ST8600
Motorola Categories
Cell Phone
Two-Way Radio
Baby Monitor
Cordless Telephone
Radio
More Motorola Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL