<Reassembly Notes>
Imaging Unit Reassembly
When reinstalling the Imaging Unit, the Flange to Focal Distance (FFD)
CAUTION
4
adjustment is mandatory.
Digital PCB Ass y Reassembly
NOTE
1
⑴ Before installing the Digital PCB Ass'y, insure that the two plates do not touch at the blue
line in the drawing.
⑵ Dress the Digital PCB leads so they fit in the recess as shown.
Must not touch!
Fig. 052 Imaging Unit Reassembly 1
Red Lead wire
Dress cable
properly.
Prevents Breaking
of wires
Fig. 053 Imaging Unit Reassembly 2
20