Specifications for the Power Supplies, Switches, and Fan
Power Requirements
Total input BTU
Total output BTU
9 The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on 100 VAC
for the 350-W and 715-W power supplies and 115 VAC for the 1100-W power supply.
10 The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on 100 VAC
for the 350-W and 715-W power supplies and 115 VAC for the 1100-W power supply.
Table 35: Fan Module Environmental and Physical Specifications
Environmental Ranges
Operating temperature
Storage temperature
Relative humidity
Altitude
Physical Specification
Dimensions (H x D x W)
Weight (for three fans)
Operating Specification
Airflow
Cisco Catalyst 9300 Series Switches Hardware Installation Guide
78
9
• PWR-C1-1100WAC: 4263 BTUs per hour, 1250 W
• PWR-C1-715WAC: 2742 BTUs per hour, 804 W
• PWR-C1-350WAC: 1357 BTUs per hour, 398 W
10
• PWR-C1-1100WAC: 3751 BTUs per hour, 1100 W
• PWR-C1-715WAC: 2438 BTUs per hour, 715 W
• PWR-C1-350WAC: 1194 BTUs per hour, 350 W
23 to 176°F (–5 to 80°C)
–40 to 185°F (–40 to 85°C) up to 15,000 ft (4500 m)
5 to 95% (noncondensing)
Up to 13,000 ft (4000 m)
1.62 x 1.73 x 4.24 in. (4.11 x 4.39 x 10.76 cm)
0.48 lb (0.21 kg)
20 cfm