To adjust the pilot flame, turn this screw. Clockwise
lowers the flame while counter-clockwise raises it.
Move the controls left or right until the flame
looks correct. Pushing to the right gives the
flame more air, making it more blue.
Pushing to the left gives the flame less air,
making it more orange.
NOTE: If the air control is all the way open,
yet the flames remain sooty, shut off gas to
the fireplace and contact a qualified gas
service technician.
Correct
Flames should be blue at the
base, yellow-orange on the top.
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
Standard
Screwdriver
NOTE: The logs must be installed correctly to
monitor the flame while adjusting the air shutter.
Not Enough Air
If the flames are over 14" tall or sooty on
the ends, open the air shutter.
Air Shutter
Too Much Air
If the flames are all blue and
short, close the air shutter.