Factory-Built (Metal) Wood-Burning Fireplace Requirements; Hearth Requirements; Leveling Bolts - Travis Industries DVL Insert EF II Owner's Manual

Travis industries direct vent fireplace insert owner's manual
Hide thumbs Also See for DVL Insert EF II:

Advertisement

Installation (for qualified installers only)

Factory-Built (Metal) Wood-Burning Fireplace Requirements

N O T E : Any parts that are removed must be removed in a way that would allow them to be re-installed if the
insert is ever removed.
The damper ("A") and grate (with log set) ("B") must be removed (see the illustration below)
The smoke shelf ("C"), internal baffles ("D"), screen ("E"), masonry lining or refractory ("G" & "I"), and metal
or glass doors ("F") may be removed (if applicable)
The fireplace must be permanently marked to
indicate that it has been altered and is no longer
suitable for burning solid fuel (wood), unless the
removed parts are re-installed. Cutting of any sheet
metal parts is prohibited (removal of rivets or screws
is acceptable).
The insulation ("H"), and any structured rigid frame
members must not be removed or altered (side and
top of door frame, side and top of the face of the
fireplace, metal sides, etc.).
The metal floor ("J") may be removed to allow
additional room for installation of the insert. If the
floor is removed the insert must be placed directly
on the metal base of the metal fireplace.

Hearth Requirements

Leveling Bolts

NOTE
To access the rear leveling bolts remove these
access plates (replace access plate and
gasket after adjustment).
Front Leveling Bolts
4080123
Use a 1/2" socket wrench
(with extension) to adjust
the leveling bolts.
Rear Leveling Bolt
9