To adjust the pilot flame, turn this screw (NOTE: if totally
unscrewed gas will come out of this port). Clockwise
lowers the flame while counter-clockwise raises it.
a
Remove and discard the three
screws using a slotted screwdriver
of Torx T-20.
Slotted
Screwdriver
(or T-20 Torx)
c
Install the LP regulator. Use
the screws included with the
LP regulator. Tighten to
approximately 25 Lbs. torque.
Slotted
Screwdriver
(or T-20 Torx)
The pilot flame must contact the thermocouple and
thermopile (see the illustration below). Adjust the pilot up or
down as necessary.
Standard
Screwdriver
b
Remove and discard the
regulator, diaphram, spring
and center post.
NOTE: Make sure the
regulator gasket is correctly
aligned before installation.
d
Place the LP
label on the base
near the gas
control valve.