Minimum Clearances; Mantel Clearances - Travis Industries DVL Insert EF II Owner's Manual

Travis industries direct vent fireplace insert owner's manual
Hide thumbs Also See for DVL Insert EF II:

Advertisement

10
Installation (for qualified installers only)
Clearances
Due to the high temperature of the heater, it should be located out of traffic and away from
furniture and draperies.
Side
k
Wall
l

Mantel Clearances

The maximum mantel depth is 12".
NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing.
If it does, it is considered a mantel and must meet the mantel requirements listed in this manual.
Above Base of Insert (n)
© Travis Industries
n
37+"
36"
35"
Mantel Height
34"
33"
32"
31"

Minimum Clearances

k
l
m
n
x
m
* The non-combustible top facing must extend
35-1/2" above the base of the insert or to the
bottom of the mantel (whichever is less).
** Measured from the base of the insert.
x
Maximum Mantel Depth
0" 1" 2" 3" 4" 5" 6" 7" 8" 9" 10"11" 12"
4080123
Sidewall to Insert
Side Facing
Top Facing*
Mantel*
Extension onto Hearth
100-01174_002
4"
4"
35-1/2"**
35-1/2"**
1-1/4"