VENT TERMINATION REQUIREMENTS:
IT IS RECOMMENDED THAT YOUR PELLET STOVE BE INSTALLED BY AN AUTHORIZED DEALER/INSTALLER.
Letter
Minimum Clearance
A
24 in (61 cm)
B
48 in (122 cm)
C
12 in (30 cm)
D
24 in (61 cm)
E
24 in (61 cm)
F
12 in (30 cm)
G
12 in (30 cm)
H
3 ft (91 cm) within a height
of 15 ft (4.5 m) above the
meter/regulator assembly
I
3 ft (91 cm)
J
12 in (30 cm)
K
24 in (61 cm)
L
7 ft (2.13 m)
Above grass, top of plants, wood, or any other combustible materials.
Beside/below any door or window that may be opened. (18" (46 cm) if outside
fresh air installed.)
Above any door or window that may be opened. (9" (23 cm) if outside fresh air
installed.)
To any adjacent building, fences and protruding parts of the structure.
Below any eave or roof overhang
To outside corner.
To inside corner, combustible wall (vertical and horizontal terminations).
To each side of center line extended above natural gas or propane meter/
regulator assembly or mechanical vent.
From any forced air intake of other appliance
Clearance to non-mechanical air supply inlet to building, or the combustion air
inlet to any appliance.
Clearance above roof line for vertical terminations.
Clearance above paved sidewalk or paved driveway located on public property.
Opens
D
F
Opens
B
A
Termination Cap
G
Air Supply Inlet
Description
B
G
I
Restriction Zone
Gas Meter
(Termination not allowed)
GFI60 Wood Pellet Insert
G
K
E
G
C
L
Opens
H