JRC JCY-1800 Instruction Manual page 57

Voyage data recorder
Hide thumbs Also See for JCY-1800:
Table of Contents

Advertisement

4.5.6.5.
4.5.6.6. Analog Signal Converting Board (CEF-60) setup
The parameter setup of the following input signal is set up by the strap on PCB.
Other setup items are set up with maintenance software.
Refer to the instruction manual of maintenance software for details
1) Setting parameter of each channel
Items
Input channel use
Input signal
Range
2) Setting strap on the PCB (CEF-60)
CH0
CH1
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Parameter
YES (enable) / NO (disable)
Voltage
Current
±1V
±5V
4-20mA
±10V
CH2
CH3
51
4. Installation, Setup and Check
Set "YES" by connecting analog signal or
"NO" by connecting no signal.
Chooses the kind of signal.
Choose the range of input signal.
A range setup is changed according to the
kind of signal.
CH4
CH5
Remark
CH6
CH7
DOC No. 7ZPNA4014