Troubleshooting; Error Messages - Philips VARILITE VL1100 LED User Manual

Hide thumbs Also See for VARILITE VL1100 LED:
Table of Contents

Advertisement

VARI
LITE® - VL1100 LED

Troubleshooting

Error Messages

If a problem occurs during luminaire calibration, at the end of the calibration sequence the Menu
Display will cycle through any applicable error message(s) until the end of the list is reached. To
review the error messages again, it will be necessary to access them using the Status function.
To access error messages:
Step 1. Press [Menu].
Step 2. Press [Up] / [Down] arrows until Fixture appears. Press [Enter].
Step 3. Press [Up]/ [Down] arrows to access Status. Press [Enter]. (Display will now scroll
through any error messages or display OK if no errors.)
Pan/No Sens
Pan/Encoder/Fail
Tilt/No Sens
Tilt/Encoder/Fail
Index/No Sens
Rot Gobo/No Sens
LED Failure Mode
64
VL1100 LED HP U
AND
Display
OK
No message displayed but there will be no response from the LED array.
'
M
SER
S
ANUAL
Table A-1: Error Messages
Message...
No Errors Found
Pan sensor not found.
Pan encoder failure.
Tilt sensor not found.
Tilt encoder failure.
Gobo Index sensor not found.
Rotating Gobo sensor not found.