Amplifier Units with Connectors
● Mounting
Mounting Connectors
1. Insert the Master or Slave Connector into the Amplifier Unit until it
clicks into place.
2. Join Amplifier Units together as required after all the Master and
Slave Connectors have been inserted.
3. Attach the seals (provided as accessories) to the sides of Master
and Slave Connectors that are not connected to other Connectors.
Sticker
Note: Attach the stickers to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit for which the Connector is to be
removed away from the rest of the group.
2. After the Amplifier Unit has been separated, press down on the
lever on the Connector and remove it. (Do not attempt to remove
Connectors without separating them from other Amplifier Units
first.)
http://www.ia.omron.com/
Insert
Sticker
Press down
Lever
Remove
Mounting End Plate (PFP-M)
Depending on how it is mounted, an Amplifier Unit may move during
operation. In this case, use an End Plate.
Before mounting an End Plate, remove the clip from the master
Amplifier Unit using a nipper or similar tool.
Clip
The clip can also be removed using the following mechanism, which
is incorporated in the construction of the section underneath the clip.
1. Insert the clip to be removed into the slit underneath the clip on
another Amplifier Unit.
2. Remove the clip by rotating the Amplifier Unit.
Rotate
Pull Strengths for Connectors (Including Cables)
E3X-CN11: 30 N max.
E3X-CN12: 12 N max.