Equipment Set-Up And Close Procedures; Vent Adjustment; Daily Cleaning Procedure - Henny Penny HC-903 Service Manual

Heated holding cabinet
Table of Contents

Advertisement

EQUIPMENT SET-UP AND
CLOSE PROCEDURES
The Introduction and Installation sections of
this manual should be read before operating
the cabinet.
This section contains an explanation of all
controls and components and information
on operating procedures and daily mainte-
nance.
Heated air inside the cabinet is circulated
over 2 heating coils and across a water pan.
The warm, moist air is then forced down-
ward through air ducts on each side of the
unit. The heated air is dispersed over and
under the product from openings in the air
ducts. These openings are varied in size to
promote uniformity of heated air throughout
the cabinet.
Set-up
Place the power switch in the ON position.
If humidity is desired, remove the water pan
and put approximately 1" of hot water in the
pan. Then return the pan to the unit.
NOTE: Be sure to push the water pan in
as far as it will go so that it does not
block air from the temperature probe.
This will assure proper operation of the
controls.
The display will increase in temperature,
indicating the cabinet is heating. When the
operating preset temperature is reached the
"HEAT ON" LED will turn off and the display
should stay at the preset temperature.
Once the preset temperature shows on the
display, product can then be placed in the
cabinet. Slide a tray of product into the
racks, close the door, and press the appro-
priate timer button on the controls.

Vent Adjustment

The vent setting corresponds to the number of
trays of product. With one tray of product, set
the vent at No. 1. With two trays of product, set
the vent at No. 2, and so on.
Close

Daily Cleaning Procedure

1.
Move the power switch to the OFF
position.
2. Disconnect the electrical supply to the
cabinet.
WARNING: Allow the unit to cool before
cleaning by opening the door(s) slightly.
3. Remove trays and racks from the inside of
the unit and clean them thoroughly with a
hot solution of McD All Purpose Concen-
trate (APC) (HCS) from the sink
proportioner.
CAUTION: Most surfaces of the unit can be
cleaned with a soft cloth, cleanser, and
water. DO NOT USE ABRASIVE CLEANERS.
4. Remove the water pan and clean it with a
soft cloth and a hot solution of McD APC
(HCS) from the sink proportioner.
5. Wipe the control panel with a damp cloth.
Do not splash water around the controls.
6. Clean the exterior of the cabinet with a
damp cloth.
NOTE: The doors can be easily pulled from the
hinges for easy cleaning.
7. Clean the interior of the cabinet thoroughly
with a cloth and a hot solution of McD APC
(HCS) from the sink proportioner.
8. Put the side racks and water pan back into
the cabinet.
9. Leave the door open over night to allow the
unit to dry out.
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents