42
en | Adjustment of detection settings
3.
P
8.3

Relay settings

Notice!
The alarm output is only configurable for flame or smoke alarms. Forwarding alarms coming
from Intelligent Video Analytics is not possible.
The camera includes a built-in relay that switches in case of a flame or a smoke alarm. The
relay is switched during the alarm and returns to its initial state after the alarm.
You can configure the switching behavior of the output:
Go to Alarm > Interfaces > Alarm Outputs
Idle state
1.
2.
Output name
An individual name can be assigned to the relay. The name is shown on the button. The Live
page can also be configured to display this individual name.
Toggle
You can click the button to switch the alarm output manually (for example, for testing
purposes). A green check mark appears to indicate that the relay switches.
Notice!
Check carefully the toggle settings before you continue.
Press Set to apply the settings.
2017.06 | 6.0 | F.01U.318.200
Select On and press Set.
Automasks for Smoke were deleted.
Under Idle state select the desired initial state of the relay.
Select from the following options:
Closed: the relay is normally closed.
Open: the relay is normally open.