Removal Procedure
1. Set the power switch on the system unit to Off.
2. Do the "Rear Cover Removal" on page 4-12.
3. Disconnect the cable to the IBM 5085 Dials Feature from the RT PC
5080 Peripheral Adapter.
4. Remove the clamping device and disconnect the Dials Feature cable.
Replacement Procedure
1. Connect the Dials Feature cable connector to the cable Peripheral Cable
Kit and install the clamping device.
2. Connect the cable to the RT PC 5080 Peripheral Adapter.
3. Do the "Rear Cover Replacement" on page 4-13.
4. Set the power switch on the system unit to On.
10-146-2