Battery Removal
4-22
Service Manual
DANGER
Fire, explosion, and severe burn hazard. Do not recharge, disassemble,
heat above 100
0
C, solder directly to the cell, incinerate, or expose cell
contents to water. Keep away from children. Replace with IBM part
number 6299201 only or a battery that has been specifically classified
by Underwriters Laboratories for use with the IBM 6150 System Unit
and is so marked to indicate such classification. Use of another may
present risk of fire or explosion.
1. Do the "Front Cover Removal" on page 4-10.
2. Disconnect the battery cable from the operator panel board.
3. Open the battery box and remove the battery.