Hide thumbs Also See for PHG6A24:
Table of Contents

Advertisement

3. Never test for gas leaks with an open flame. Use commercially
available soap solution made specifically for the detection of leaks
when checking all connections, as specified on Page 10 of these
instructions.
4. Always install furnace to operate within the furnace's intended tem-
perature-rise range with the duct system and within the allowable
external static pressure range, as specified on the unit name/rating
plate, specified in Table 6 of these instructions.
5. This equipment is not to be used for temporary heating of buildings
or structures under construction.
LIMITATIONS
These units must be installed in accordance with the following:
In U.S.A.:
1. National Electrical Code, ANSI/NFPA No. 70 - Latest Edition
2. National Fuel Gas Code, ANSI Z223.1 - Latest Edition
3. Gas-Fired Central Furnace Standard, ANSI Z21.47a. - Latest Edi-
tion
4. Local building codes, and
5. Local gas utility requirements
Table 1: Unit Limitations
Model
PHG6A24
PHG6A30
PHG6B36
PHG6B42
PHG6B48
PHG6B60
Johnson Controls Unitary Products
Unit Voltage
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
In Canada:
1. Canadian Electrical Code, CSA C22.1
2. Installation Codes, CSA - B149.1.
3. Local plumbing and waste water codes, and
4. Other applicable local codes.
Refer to unit application data found in this document.
After installation, gas fired units must be adjusted to obtain a temperature
rise within the range specified on the unit rating plate.
If components are to be added to a unit to meet local codes, they are to
be installed at the dealer's and/or customer's expense.
Size of unit for proposed installation should be based on heat loss/heat
gain calculation made according to the methods of Air Conditioning
Contractors of America (ACCA).
This furnace is not to be used for temporary heating of buildings or
structures under construction.

Unit Limitations

Applied Voltage
Min
Max
187
252
187
252
187
252
187
252
187
252
187
252
5322625-UIM-A-0417
Outdoor DB Temp
Max (°F)
125
125
125
125
125
125
3