Removal Of Propeller Fan And Fan Motor - Daikin FTK25JV1NB Manual

Inverter pair
Table of Contents

Advertisement

Si-86.book Page 111 Friday, June 23, 2000 10:26 AM
SIE-86
2.4

Removal of Propeller Fan and Fan Motor

Procedure
Step
Disconnect the fan motor
connector S70.
1
The lead-wires of the fan
motor can be disengaged
by passing through the
clearance between the
heat exchanger and the
switch box.
2
The propeller fan can be
removed when the washer
faced nut
(M8) is removed.
3
Remove two screws for
removing the fan motor.
The lead wires are
disengaged by raising the
hooks which fix the lead
wires.
4
Remove the fan motor.
Removal Procedure
Warning
Be sure to turn off all power supplies before disassembling work.
Procedure
For RK25J, RK35J, RX25J, RX35J
Points
Remove the external plates and
the drip proof cover protecting
the electric parts.
Be sure to avoid forgetting to
restore the shelter and to avoid
loosing or damaging it.
When restoring, match the
mark of the propeller fan with the
D-cut of the motor shaft.
The fan should be restored so
that the mark
will be at upper
part of the fan motor.
111

Hide quick links:

Advertisement

Table of Contents
loading