633/635
Users Manual
If no reference clock measurement is being made, remove the plug
from the REF jack to extend battery life.
2-10. E-Bit Sync
E-Bit Sync
T1
If E-Bit is the selected signaling type (chosen with the SIGNALING TYPE
key), the E-Bit Sync results screen will display Yes or No to indicate whether
or not the span is in E-Bit sync. If E-Bit is not the selected signaling type, the
E-Bit Sync results screen is not accessible.
2-11. DS1 Level (volts, peak-to-peak)/DS1 Level (dBDSX)
DS1 Level
DS1 Level
T1
DS1 Level (volts, peak-to-peak)
When monitoring an in-service span, it may be useful to read the level of the
T1 signal in volts, peak-to-peak; therefore, the DS1 level may be viewed both
in dBDSX and volts, peak-to-peak. See section 3-6.
2-8
Note
E-Bit
Int
RB
Int
Yes
CSU
6.00vp-p
0.00dBD
CSU
abn10f.eps
abn10f.eps