Optical safety
The equipment contains Class 1 laser component according to IEC 60825-1 (par. 5).
The laser source is placed in the optional SFP plug-in, which has to be installed in the Core-E unit. The
laser source is placed in the left side of the SFP plug-in.
According to the IEC 60825-1 the explanatory label is not sticked on the equipment due to the lack of
space.
Microwave radiations (EMF norms)
Equipment emitting RF power (Reminder from site preparation procedure):
The site must be compliant with ICNIRP guidelines or local regulation if more restrictive.
The following rules should be strictly applied by Customer:
Non authorized persons should not enter the compliance boundaries, if any, for the general public.
Compliance RF boundaries, if any, related to Electro Magnetic Field exposure must be marked.
Workers should be allowed to switch-off the power if they have to operate inside compliance bound-
aries.
Assure good cable connection.
Install the antenna as high as possible from floor or area with public access (if possible the cylinder
delimitating the compliance boundaries, if any, or the cylinder corresponding to the transmission area
directly in front of antenna with the same diameter as the antenna, more than 2 meters high).
Install the antenna as far as possible from other existing equipment emitting RF power.
Anyway remind that someone standing in front of the 9500 MPR-E antenna may cause traffic shutdown.
Place the relevant stickers:
On the site when applicable (when people can cross the compliance boundaries and/or the transmission
area of the antenna, i.e. roof top installation)
Warning label "Do not stand on the antenna axis"
On the mast (front side)
EMF emission warning sign (Yellow and black) to be placed at bottom of antenna, visible by someone
moving in front of the antenna (roof top installation)
On the antenna (rear side)
EMF emission warning sign, placed on the antenna.
9500 MPR Rel. 3.1
38/980
3DB18809AAAA Issue 1
CLASS 1 LASER PRODUCT
EMF emission warning sign
Safety, EMC, EMF, ESD Norms and Equipment Label-