9500 MPR
Installation Practices
PN 3EM23953AB 01
R01.02, Issue 01, February 2010

Advertisement

loading

Summary of Contents for Alcatel-Lucent 9500 MPR

  • Page 1 9500 MPR Installation Practices PN 3EM23953AB 01 R01.02, Issue 01, February 2010...
  • Page 2 NOTICE This manual applies to 9500 MPR R01.02 software. Release notes describing revisions to this software may impact operations described in this manual. This transfer of commodities, technology, or software, if from the United States, is an export in accordance with the U.S.
  • Page 3 ..........1-39 Chart-7 Route and Terminate 9500 MPR Shelf Power Cables ......1-43...
  • Page 4 3EM23953AB Issue 01, February 2010 Chart-22 Assembly CSM to PC Cable ......... . . 1-141 Table of Contents...
  • Page 5 3EM23953AB Issue 01, February 2010 9500 MPR Installation Practices List of Figures Figure 2-1. Sample Floor Plan ........... . . 1-5 Figure 2-2.
  • Page 6 9500 MPR Shelf Screw Locations ........
  • Page 7 3EM23953AB Issue 01, February 2010 Figure 10-7. ODU Attached to Integrated Antenna ........1-73 Figure 11-1.
  • Page 8 3EM23953AB Issue 01, February 2010 Figure 16-2. DS1 37 Pin DSUB Customer Interconnect Detail ......1-116 Figure 16-3.
  • Page 9 3EM23953AB Issue 01, February 2010 9500 MPR Installation Practices List of Tables Table 2-A. Rack Type and Options ..........1-7 Table 7-A.
  • Page 10 3EM23953AB Issue 01, February 2010 List of Tables viii...
  • Page 11: Recommended Tools

    This chart provides instructions to unpack and inspect the 9500 MPR radio and to report any shipping damage or missing parts. GENERAL The 9500 MPR radio may be shipped from the factory as an assembled rack assembly or as kits for field installation. Alcatel-Lucent provides expert Installation Services for installations that have different requirements from the recommended configuration as outlined in this manual.
  • Page 12 Place shelf onto a level surface. Inspect MSS-8 shelves and their card cage area for visible damage. If damage is visible, contact Alcatel-Lucent to report damage and to find out what to do next. Inspect contents of box containing accessories for damage or missing parts.
  • Page 13 Equipment racks are designed for fixed-location installation. Standard and seismic rack assemblies are available. Alcatel-Lucent provides expert Installation Services for installations that have different requirements from the recommended configuration as outlined in this manual. Contact the Alcatel-Lucent Technical Support Center at 1-(888) 252-2832 for details.
  • Page 14 Chart-2 3EM23953AB Issue 01, February 2010 STEP PROCEDURE Observe the following guidelines: Verify that layouts of floor, ceiling, and walls are as indicated in applicable drawings and specifications. Verify that area dimensions and location of reference points correspond to floor plan.
  • Page 15 Chart-2 3EM23953AB Issue 01, February 2010 Figure 2-1. Sample Floor Plan Verify required space for rack. See figure 2-1. Follow chalk line to mark front baseline and end of rack. Use felt-tipped marking pen to mark anchor points for rack. See Figure 2-2, floor mounting diagram for standard rack.
  • Page 16 Chart-2 3EM23953AB Issue 01, February 2010 Figure 2-2. Floor Mounting Detail for Standard Rack .5620 DIA 4 HOLES 16.378 8.19 5.25 11.27 2.75 4.26 5.25 20.50 Floor Mounting Pattern Rear Baseplate Shown 950-0202-1 Turned out 022610 Prepare Floor...
  • Page 17 Chart-2 3EM23953AB Issue 01, February 2010 Figure 2-3. Floor Mounting Detail for Unequal Flange Seismic Rack 21.9375 11.8438 10.1875 2.8125 Front Mounting Surface of Rack Channel 2 Slots 1.625” x 3.1875 5.05 4 Slots 1” x 2.75” 5.88 Floor Mounting Pattern 950-0203-1 Unequal Flange Seismic Rack 022610...
  • Page 18 Chart-2 3EM23953AB Issue 01, February 2010 Figure 2-4. Standard Rack (PN 694-9000-006) (1 of 2) Prepare Floor...
  • Page 19 Chart-2 3EM23953AB Issue 01, February 2010 Figure 2-5. Standard Rack (PN 694-9000-006) (2 of 2) Prepare Floor...
  • Page 20 Chart-2 3EM23953AB Issue 01, February 2010 Figure 2-6. Unequal Flange Seismic Rack (PN 1AD014120046) Rack Grounding Detail (2 Places) 84.00 Standard Height 950-0207-1 21.9375” 022610 Prepare Floor 1-10...