Olivetti d-Color MF2613 Plus Service Manual page 326

Multifuction digital
Table of Contents

Advertisement

Connector
Pin
YC101
1
Connected to
2
AC inlet and
main power
switch
YC102
1
Connected to
2
fuser heater
YC103
1
Connected to
2
relay PWB
3
4
5
6
7
8
9
10
11
12
13
YC104
1
Connected to
2
interlock
3
switch
YC105
1
Connected to
2
main PWB
3
4
Service Manual
Signal
I/O
LIVE
I
NEUTRAL
I
NEUTRAL
O
LIVE
O
+24V1
O
GND
-
GND
-
GND
-
GND
-
+24V2
O
+24V2
O
+24V2
O
+24V2
O
PSSLEEPN
I
ZCROSS
O
RELAY
I
HEATRE1
I
+24V1
O
N.C
-
+24V2
I
+24V1
O
GND
-
GND
-
+5V1
O
Voltage
120 V AC
AC power input
220-240 V AC
120 V AC
AC power input
220-240 V AC
120 V AC/0 V
FH: On/Off
220-240 V AC/0 V
120 V AC
AC power to FH
220-240 V AC
24 V DC
24 V DC power to RYPWB
-
Ground
-
Ground
-
Ground
-
Ground
24 V DC
24 V DC power to RYPWB (via ILSW)
24 V DC
24 V DC power to RYPWB (via ILSW)
24 V DC
24 V DC power to RYPWB (via ILSW)
24 V DC
24 V DC power to RYPWB (via ILSW)
0/3.3 V DC
Sleep mode signal: On/Off
0/3.3 V DC (pulse) Zero-cross signal
0/3.3 V DC
Power relay signal: On/Off
0/3.3 V DC
FH: On/Off
24 V DC
24 V DC power to ILSW
-
Not used
24 V DC
24 V DC power from ILSW
24 V DC
24 V DC power to MPWB
-
Ground
-
Ground
5 V DC
5 V DC power to MPWB
2-3-2
2PX/2PY
Description
Y116670-7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-color mf2614 plus

Table of Contents