Installation Guidelines
Receiver side
Figure 3.16 All four adjustment screws are used to align the sensor at the
receiver side.
Receiver side
Figure 3.17 Light dot at the receiver side.
When the light dot is centered fasten the four screws with the
light dot still centered in the cross hair. Once the screws are
tightly fastened, remove the cross hair, flashlight and two adapt-
ers. Remount the sensors with the transmitter and sensor elec-
tronics and connect the sensor purging tubes.
NOTE
The stability of the sensor alignment depends on the stability of the
construction to which the customer's flange is mounted. If the incin-
erator wall or smoke duct is subject to movements due to, for
instance, thermal changes CD 6 will need repeated realignment.

3.1.4 ATEX Transmitter and Receiver Sensors

A hybrid cable is used to connect the transmitter sensor to the
barrier.