# Display the electrical label information about the transceiver plugged in interface GigabitEthernet
3/0/4.
<Sysname> display transceiver manuinfo interface gigabitethernet 3/0/4
GigabitEthernet3/0/4 transceiver manufacture information:
Manu. Serial Number
Manufacturing Date
Vendor Name
Table 21 Command output
Field
Manu. Serial Number
Manufacturing Date

Diagnosing transceiver modules

The switch provides the alarm function and digital diagnosis function for transceiver modules. When a
transceiver module fails or is not operating normally, you can check the alarms present on the transceiver
module to identify the fault source or examine the key parameters monitored by the digital diagnosis
function, including the temperature, voltage, laser bias current, TX power, and RX power.
To diagnose transceiver modules, execute the following command in any view:
Task
Display alarms present on the
transceiver in a specified
interface
Display the present measured
values of the digital diagnosis
parameters for the transceiver
in a specified interface
# Display the alarm information about the transceiver plugged in GigabitEthernet 3/0/1.
<Sysname> display transceiver alarm interface GigabitEthernet 3/0/1
GigabitEthernet3/0/1 transceiver current alarm information:
RX loss of signal
RX power low
Table 22
shows the alarm information that may occur to the commonly used transceivers.
Table 22 Command output
Field
transceiver current alarm information
SFP/SFP+:
RX loss of signal
TX fault
RX power high
: MY13D41001
: 2014-01-20
: HP
Description
Serial number generated during commissioning and testing of the transceiver
module.
Commissioning date.
Command
display transceiver alarm interface
[ interface-type interface-number ]
display transceiver diagnosis
interface [ interface-type
interface-number ]
67
Remarks
Available for all transceivers
If no error occurs, None is
displayed.
Available for all transceivers.
Remarks
Alarms present on the transceiver module.
Received signals are lost.
Transmission error.
The received optical power is high.