Configuring Temperature Thresholds For A Card - HP FlexFabric 12500E Installation Manual

Routing switch
Table of Contents

Advertisement

Configuring temperature thresholds for a card

Step
1.
Enter system view.
2.
Configure temperature alarm
thresholds for a card.
Displaying the temperature information on your switch
Use the display environment command to display the temperature information of the sensors on the cards,
including the current temperature and temperature thresholds.
# Display the temperature information of the cards on the switch.
<Sysname> display environment
In standalone mode:
System temperature information (degree centigrade):
-------------------------------------------------------------------------------
Slot
1
1
1
5
5
5
12
12
In IRF mode:
System temperature information (degree centigrade):
-------------------------------------------------------------------------------
Slot
1/1
1/1
1/1
1/5
1/5
1/5
1/12
1/12
Sensor
Temperature
inflow
1
21
outflow 1
24
hotspot 1
27
inflow
1
27
outflow 1
27
hotspot 1
30
inflow
1
23
outflow 1
42
Sensor
Temperature
inflow
1
21
outflow 1
24
hotspot 1
27
inflow
1
27
outflow 1
27
hotspot 1
30
inflow
1
23
outflow 1
42
Command
system-view
In standalone mode:
temperature-limit slot slot-number { inflow | hotspot | outflow }
sensor-num lowerlimit warninglimit [ alarmlimit ]
In IRF mode:
temperature-limit chassis chassis-number slot slot-number { inflow |
hotspot | outflow } sensor-num lowerlimit warninglimit [ alarmlimit ]
LowerLimit
WarningLimit
-25
-15
-15
-20
0
-10
-10
5
LowerLimit
WarningLimit
-25
-15
-15
-20
0
-10
-10
5
59
AlarmLimit ShutdownLimit
70
80
70
85
75
85
65
85
70
85
70
80
55
80
85
95
AlarmLimit ShutdownLimit
70
80
70
85
75
85
65
85
70
85
70
80
55
80
85
95
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A

Advertisement

Table of Contents
loading

Table of Contents