Indoor Unit; Ffq09/12/15/18Q2Vju - Daikin FFQ09Q2VJUFFQ12Q2VJUFFQ15Q2VJUFFQ18Q2VJURX09QMVJURX12QMVJURX15QMVJURX18QMVJU Service Manual

Inverter pair ceiling mounted cassette type ffq-q series
Table of Contents

Advertisement

Indoor Unit

1. Indoor Unit

1.1

FFQ09/12/15/18Q2VJU

Control PCB
(A1P)
1) X15A
2) X16A
3) X17A, X18A
4) X20A
5) X24A
6) X25A
7) X27A
8) X30A
9) X33A
10) X35A
11) X36A
12) X80A
13) X81A
14) HAP
15) DS1
16) F1U
X30A
DS1
X24A
X18A
X16A
X81A
X17A
X15A
X36A
7
Connector for float switch
Connector for room temperature thermistor (suction air thermistor)
Connector for indoor heat exchanger thermistor
Connector for DC fan motor
Connector for transmitter board
(when the wireless remote controller (option) is used)
Connector for drain pump motor
Connector for terminal block (for inter-unit wiring)
Connector for terminal block (for wired remote controller)
Connector for adaptor for wiring (option)
Connector for wiring adaptor for electrical appendices (option)
Connector for swing motors on decoration panel (option)
Connector for decoration panel (BYFQ60B3W1) (option)
Connector for sensor kit (BRYQ60A2W(S)) (option)
LED for service monitor (green)
DIP switch
Fuse (5 A, 250 V)
X25A
X33A
HAP
X80A
X20A
X35A
Printed Circuit Board Connector Wiring Diagram
SiUS091628EA
F1U
X27A
2P452045-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents