Table of Contents

Advertisement

Installing The Mounting Plate
• The mounting plate should be installed on a wall which can support the weight of the indoor unit.
1) Temporarily secure the mounting plate to the wall, make sure that the panel is completely level, and mark the
boring points on the wall.
2) Secure the mounting plate to the wall with screws.
Recommended mounting-plate retention spots and Dimensions
Through-the-wall hole $65mm
t
Recommended mountfng plate
retention spell (7 spots m all)
Drilling A Wall Hole And Installing Wall Embedded Pipe
� WARNING---------------
For metal frame or metal board walls, be sure to use a wall embedded pipe and wall hole cover in the feed-through hole
to prevent possible heat, electrical shock, or fire.
1) Drill a feed-through hole with a 65mm
diameter through the wall at a
downward angle toward the outside.
2) Insert a wall embedded pipe into the hole.
3) Insert a wall hole oo.,er into wall pipe.
5

Indoor Unit

Use a tape measure
as shown.
Position the end of
the tape measure at
Liquid pipe end
Gas pipe end
Drah hose
position
Inside ........ Outside
Wall hole cover
(field supply)
1>-
Applicable Unit Size*
Type [H] X [W] X [D]
CD
298
800
229
X
X
@
298
821
235
X
X
®
298
885
229
X
X
©
298
906
235
X
X
• Unit size available on name plate.
Applicable Unit Size*
Type
[H] X [W] X [D]
®
310
• Unit size available on name plate.
All dimensions are in mm.
A
B
C
800 116.5 116.5
821
126.5
128
885 116.5 116.5
906
127
127.5
Table No.4
,
I
1100
239
X
X
Table No. 5

Advertisement

Table of Contents
loading

Table of Contents