Procedure
1. Fail over the storage controller
a. On the StoreVirtual menu, select Storage Systems.
a. On the navigation pane, select the storage system, and then select Actions > Fail over storage
controller on the content pane.
b. Select the storage controller from the list if more than one is listed.
a. Select the check box next to the storage controller status, and then click Yes, fail over storage
controller.
2. Reboot the storage controller
a. On the StoreVirtual menu, select Storage Controllers.
b. On the navigation pane, select the storage controller, and then select Actions > Power off or reboot
on the content pane.
c. Click Reboot.
d. Enter the number of minutes for the system to wait before rebooting, and then click OK.
e. Review the warning message and then click Yes, reboot.
f. On the second confirmation message, select the confirmation box, and then click Yes, reboot.
3. Fail back the storage controller
a. On the StoreVirtual menu, select Storage Systems.
b. On the navigation pane, select the storage system, and then select Actions > Fail back storage
controller on the content pane.
c. Select the storage controller to fail back, and then click OK.