Download Print this page

Philips TTX400 Brochure & Specs page 53

Philips light-line system brochure

Advertisement

TTX400
TTX400 electrical units
These electrical units are designed for quick-click mounting in TTX400
trunking sections. They are for use with one or two TL5 or TL-D
lamps, with electronic (dimming) ballast (or conventional ballast in the
case of TL-D), and are available in emergency lighting versions and in
versions for the mounting of projectors. They contain all the necessary
electrical and mechanical functions. All components are screwed onto
the electrical unit. The units can be combined with any type of reflector
and are made of white sheet steel.
TMX400 is delivered with electronic ballast HFP. The dimmable version
of the TMX400 is delivered with the electronic ballast HFR, allowing
the light output of the TL5 lamps to be regulated from 3 to 100 %. This
TTX400 TL5
Electrical units
Type
TMX400
Light source
Fluorescent:
Gear
Electronic, 220 - 240 V / 50 - 60 Hz:
Option
Emergency lighting:
Master/Slave:
HFR/HFR-TD with emergency lighting: TMX400 9
for trunking 9 wires or preferably TMX400 2-CR
to be used with TTX400 7-wires (thereby in case
of non-continuous lightline, to order throughwiring
ZTX400 C1300-2 or C1600-2 as accessory)
Material
Sheet steel, white
Installation
Click-in fixation (both mechanical and electrical
connection) on trunking TTX400 with 5- or 7-wire
ribbon cable
Accessory
Blind covers (BC)
Throughwiring set to be used in combination
with TMX400 C2R onto TTX400 7, in the case of
non-continuous lightline (ZTX400 C1300-2 for
1 section 28/54 W; ZTX400 C1600 for 1 section
35/49/80 W).
Where relevant, for detailed descriptions of Lighting Controls we refer you to chapter 11, and descriptions for e.g. optics/optical covers, lamps data, photometrical diagrams, etc. to the respective sections in chapter 12.
8.52
Light-line systems
1 x or 2 x MASTER TL5 / G5 / 28, 35, 49, 54,
80 W
High Frequency Performer (HFP)
High Frequency Regulator (HFR)
High Frequency Regulator, DALI and Touch
(HFR-TD)
1 hour (EL1), 3 hours (EL3)
1 master + 1 slave (M/S), both master and slave
(M-S)
unit is ideal for (day)light-dependent control and must be mounted to
the prewired TTX400 section with 7-wire ribbon cable. The TMX400
units with conventional ballasts are supplied with an electrical
connector, starters, any necessary capacitor and lampholders. For
more control options the TMX400 can be equipped with DALI ballasts.
Especially in combination with Linesense controls DALI solutions offer
even greater control and energy savings.
TMX400 is deliverable in versions with in-built 3-hour or 1-hour
emergency lighting. For configuration of both emergency lighting and
regulation or DALI, TTX400 9-wires is to be used with TMX400 9. The
new solution of standard TTX400 7-wires with new units TMX400
C-2R is recommended.
TTX400 TL-D
Electrical units
Type
TMX400
Light source
Fluorescent:
Gear
Electro magnetic (low loss), 230 V / 50 Hz:
Electronic, 220 - 240 V / 50 - 60 Hz:
Option
Emergency lighting:
Master/Slave:
HFR/HFR-TD with emergency lighting: TMX400 9
for trunking 9 wires or preferably TMX400 C-2R
to be used with TTX400 7-wires (thereby in case
of non-continuous lightline, to order throughwiring
/ ZTX400 C1300-2 or C1600-2 as accessory)
Material
Sheet steel, white
Installation
Click-in fixation (both mechanical and electrical
connection) on trunking TTX400 with 5- or 7-wire
ribbon cable
Accessory
Blind covers
Throughwiring set to be used in combination with
TMX400 C-2R onto TTX400 7, in the case of
non-continuous lightline (ZTX400 C1300-2 for
1 section 28/54W; ZTX400 C1600 for 1 section
35/49/80 W)
1 x or 2 x MASTER TL-D / G13 / 36, 58 W
Inductive (I)
Inductive with possible mounting of capacitor in
parallel (IKP)
Inductive, parallel compensated (IC)
High Frequency Performer (HFP)
High Frequency Regulator (HFR)
High Frequency Regulator, DALI and Touch
(HFR-TD)
1 hour (EL1), 3 hours (EL3)
1 master + 1 slave (M/S)
both master and slave (M-S)
2-lamps lampholder with small width (F32)
Philips indoor luminaires

Advertisement

loading

This manual is also suitable for:

Maxos tl5Maxos tl-dTetrix ttx150