Philips light-line system brochure

Advertisement

Maxos
Maxos electrical units
The electrical units for Maxos trunking sections can hold 1 or 2
TL5 or TL-D lamps and are designed for quick and reliable click-in
mounting. They are made of steel with a white or silver coating.
The electrical units can be equipped with HFP electronic ballasts, HFR
dimming ballasts (allowing light output of a TLD-lamp to be regulated
from 3 to 100%), HF-DALI ballasts or low-loss conventional ballasts.
HFR and HF-DALI units must be mounted to 7-wire trunking sections.
The conventional ballasts are available parallel compensated (IC) or
inductive (I).
Maxos TL5
Electrical units
Type
4MX691
Lamp
Fluorescent:
Gear
Electronic, 220 - 240 V / 50 - 60 Hz:
Option
Emergency lighting:
Material
Sheet steel in white (WH) or silver (SI)
Installation
Click-in fixation (mechanical and electrical) on
trunking
Where relevant, for detailed descriptions of Lighting Controls we refer you to chapter 11, and descriptions for e.g. optics/optical covers, lamps data, photometrical diagrams, etc. to the respective sections in chapter 12.
8.20
Light-line systems
1 x or 2 x MASTER TL5 / G5 / 35, 54, 49, 80 W
High Frequency Performer (HFP)
High Frequency Regulator (HFR)
High Frequency Regulator, DALI (HFD)
1 hour (EL1)
3 hours (EL3)
Special electrical units equipped with an emergency battery pack for
1 or 3 hours (EL1/EL3) are available. These units must be used with
7-wire trunking sections. If trunkings with double wiring are used, one
flat ribbon cable will be connected to the central battery. This provides
a completely separate emergency lighting circuit.
Some 2-lamp TL-D reflectors need dedicated electrical units (F32)
with a short distance between the lamps. On request, the TL-D
electrical units can be upgraded from IP20 to IP40 with an IP40 set
that is available as an accessory.
Maxos TL-D
Electrical units
Type
4MX091
Lamp
Fluorescent:
Gear
Electro magnetic (low loss), 230 or 240 V / 50 Hz:
Electronic, 220 - 240 V / 50 - 60 Hz:
Option
Emergency lighting:
2-lamp lampholder of 32 mm (F32) to be used in
facetted and aluminum reflectors, standard is 115
mm
Master/slave unit: pair of electrical units one with
gear (M) one without gear (S)
Material
Sheet steel in white (WH) or silver (SI)
Installation
Click-in fixation (mechanical and electrical) on
trunking
Remarks
Dedicated IP40 sets for upgrading from IP20 to
IP40
1 x or 2 x MASTER TL-D / G13 / 36, 58 W
Inductive, parallel compensated (IC)
High Frequency Performer (HFP)
High Frequency Regulator (HFR)
High Frequency Basic (HF-Dali)
1 hour (EL1), 3 hours (EL3)
Philips indoor luminaires

Advertisement

loading

This manual is also suitable for:

Maxos tl5Maxos tl-dTetrix ttx150