Environmental Conditions
Temperature/
Operating
Humidity
Storage
Acoustic noise (operating)
Drip proof function*
The value measurements are equivalent to JISC0920 (IEC60529:2001) standard. Therefore, safety standard appli-
cation, and failure and breakage of the printer are not guaranteed.
106
5 to 45°C {41 to 113°F}, 10 to 90% RH (See the operating temperature and
humidity range below.)
-20 to 60°C {-4 to 140°F}, 10 to 90% RH (except for paper)
[%RH]
90
80
60
Operating
environment
40
range
20
10
0
0
10
Approximately 55 dB (bystander position)
Note:
The values above are measured in the Epson evaluation condition.
Acoustic noise differs depending on the paper used, printing contents,
and the setting values, such as print speed or print density.
IPX2 equivalent
Note:
At front eject position. Excluding the cover open lever area.
34°C, 90%
40°C, 65%
45°C, 50%
[°C]
20
30
40
50
Ambient temperature