Connecting the Cash Drawer
Required specifications of cash drawers
Specifications of drawers differ depending on makers or models. When you use a drawer other than specified,
make sure its specification meets the following conditions.
Otherwise, devices may be damaged.
The load, such as a drawer kick solenoid, must be connected between pins 4 and 2 or pins 4 and 5 of the
drawer kick connector.
When the drawer open/close signal is used, a switch must be provided between drawer kick connector pins 3
and 6.
The resistance of the load, such as a drawer kick solenoid, must be 24
1A or less.
Be sure to use the 24V power output on drawer kick connector pin 4 for driving the equipment.
Drawer Connection Diagram
F.G
Printer side
Do not connect both the optional external buzzer and the cash drawer to the printer at the
same time by using a branched connector.
When the optional external buzzer is enabled with the memory switch (customized values) (see
"Software Settings" on page
use a cash drawer.
Two driver transistors cannot be energized simultaneously.
Leave intervals longer than 4 times the drawer driving pulse when sending it continuously.
Drawer kick connector
1
With shielded
2
3
4
+24V
5
6
43), a cash drawer cannot be used. Be sure to disable it when you
or more or the input current must be
Drawer kick
solenoid
Drawer open/
close switch
User side
[Drawer kick side]
Chapter 2 Setup
6 5 4 3 2 1