2-2-24. Microphone Unit

1. Refer to Sections from 2-2-3 to 2-2-5 and
disassemble the unit up to "Handle Assem-
bly" removal.
2. Refer to Sections from 2-2-22 to 2-2-23 and
disassemble the unit up to "Microphone Unit
Assembly" removal.
3. Slightly remove the sheet attached to the
microphone cover.
n
When reinstalling the microphone unit, attach
the sheet to the original position.
4. Remove the three screws of a, and remove
the microphone case.
5. Remove the screw of b and remove the
microphone cover.
6. Disconnect the harness (KSW53-MA161)
(CN3) and the microphone unit harness
(CN1, CN2) from the MA-161 board.
7. Remove the two screws of c, and remove
the MA-161 board.
8. Disconnect the harnesses (KSW53-RM213)
(CN1) from the RM-213 board.
9. Remove the screw of d, and remove the
RM-213 board.
10. Reinstall the microphone unit by reversing
the steps of removal.
2-22
Sheet
Microphone cover
Microphone cover
a
: P2 tapping 2 x 5
b
: P2 tapping 2 x 5
d
CN1
RM-213 board
Harness
(KSW53-RM213)
CN1
Remove slightly.
Microphone unit
Microphone case
b
a
Microphone unit
Harness
(KSW53-MA161)
CN2
MA-161 board
CN3
c
c
: P2 tapping 2 x 5
d
: P2 tapping 2 x 5