Fujitsu AOU48RLXFZ Design & Technical Manual page 160

Hybrid flex inverter system
Table of Contents

Advertisement

Example 7 (Not good)
Branch box 1
Outdoor unit
(Primary type)
Indoor unit 1
Indoor unit 2
Model
Outdoor unit
AOU48
Indoor unit 1
ARU12
Indoor unit 2
ARU9
Indoor unit 3
ARU9
Indoor unit 4
ARU9
Indoor unit 5
ARU9
Indoor unit 6
ARU9
Indoor unit 7
ARU9
Branch box 1
UTP-PU03A
Branch box 2
UTP-PU03B
Branch box 3
UTP-PU03B
Example 8 (Not good)
Branch box 1
Outdoor unit
(Primary type)
Indoor unit 1
Indoor unit 2
Model
Outdoor unit
AOU48
Indoor unit 1
ASU7
Indoor unit 2
ASU7
Indoor unit 3
ASU7
Indoor unit 4
ASU7
Indoor unit 5
ASU7
Indoor unit 6
ASU7
Indoor unit 7
ASU7
Indoor unit 8
ASU7
Indoor unit 9
ASU7
Branch box 1
UTP-PU03A
Branch box 2
UTP-PU03B
Branch box 3
UTP-PU03B
Indoor unit 3
Indoor unit 4
Total
Connectable indoor
Capacity
capacity
unit capacity (BTU/h)
(BTU/h)
Min.
(BTU/h)
48000
48000
12000
9000
2 80%
9000
1
9000
38400
66000
9000
9000
9000
-
-
-
-
-
-
Indoor unit 3
Indoor unit 4
Total
Connectable indoor
Capacity
capacity
unit capacity (BTU/h)
(BTU/h)
(BTU/h)
Min.
48000
48000
7000
7000
7000
2 80%
7000
1
7000
38400
63000
7000
7000
7000
7000
-
-
-
-
-
-
- (06 - 06) -
Branch box 2
(Secondary type)
Indoor unit 5
Indoor unit 6
Indoor unit 7
Max.
3 130%
62400
62400 < 66000 → Not good
-
-
-
-
-
-
Branch box 2
(Secondary type)
Indoor unit 5
Indoor unit 6
Indoor unit 7
Max.
3 130%
Not good → Because nine indoor
units are connected
62400
-
-
-
-
-
-
Branch box 3
(Secondary type)
Capacity ratio
138%
Judgement
3 <
1
-
-
-
Branch box 3
(Secondary type)
Indoor unit 8
Indoor unit 9
Judgement
-
-
-