Gaskets

Check door and glass gaskets for seal integrity.
The gaskets should be soft enough to be somewhat
resilient to the touch. Over time, gaskets will compress
and harden. Replace worn-out or hardened gaskets with
the appropriate size material available from your local
Authorized Jøtul Dealer.
To check the seal of the front doors, close and latch the
doors on a dollar bill and slowly try to pull the dollar bill
free. The seal is too loose if the bill can be easily re-
moved. Adjust the door latch and test again.
Gasket Replacement
See the chart below for replacement gasket
specifications. See also fig. 20 for locations.
1. Remove the old gasket material with a pliers and
thoroughly clean the channel with a wire brush.
2. Lay out the new gasket around the channel to
determine length. Trim the gasket to leave 1" excess.
3. Apply a small bead of furnace cement in the channel.
4. Lightly press the new gasket into the channel, being
careful to avoid compressing or stretching it. Trim the
gasket further as necessary to allow the tail end to
slightly overlap the other end.
5. Wait ten minutes to allow the cement to set and
then close and latch the doors. Reopen the doors and,
using a damp cloth, wipe away any excess cement
that may be squeezed out from under the gasket.
Replacement Gaskets
Glass
LD .250 Fiberglass Rope
Door
LD .350 Fiberglass Rope
Front
LD .360 Fiberglass Rope
Air Manifold, Outer
LD .250 SA Fiberglass Rope 30"
Air Manifold, Inner
.125 x 8 mm Flat SA
52"
200024
70"
100034
78"
100034
129644
20"
127215
Jøtul C 350 Winterport 138376_Rev_Q 2 / 17
Blower Maintenance
In order to ensure that the blower delivers many years
of reliable performance, you should inspect it regularly
and clean it of any household dust and debris that may
have accumulated. This is particularly important if
there are any pets in the home.
Always disconnect the blower from its power
source before cleaning. Use a vacuum with soft
brush attachment to clean the blower housing and
compartment, as well as the area under the insert
firebox.