The gas connection to the appliance is effected by means of a suitable
coupling tube fitting L8, DIN 2353-ST, complying with EN 1949 (e. g. Ermeto).
The gas connection may only be carried out by a qualified personnel.
Following proper installation, a testing for leakage and a flame test must be car-
ried out by *qualified personnel in compliance with EN 1949 .
A certificate of testing must be issued.
* qualified personnel
Qualified personnel are accredited experts who are able, by virtue of their training and knowledge,
to vouch for the correct implementation of the leakage test.
A A T T T T E E N N T T I I O O N N
20 Nm
15 Nm
max
max
Gas supply
oven
connection
gas supply
Gas pressure
Category
I
3P(30)
mbar
30
BE
DK
DE
FI
FR
GR
IE
IS
IT
LU
NL
NO
AT
PT
SE
CH
ES
UK
Gas valve
Refrigerator
The refrigerator must be equipped with a gas cock
in the supply line to allow the supply to be disconnected.
Such a cut-out device must be readily accessible to the
user.
I
I
3P(50)
3P(37)
37
50
29
I
I
3+
3B/P(50)
28-37
30-37
Gas burner
Refrigerator
I
3B/P(30)
50
30

Hide quick links: