Advertisement

RM2351
RM2510
RM2354
RM2551
RM2410
RM2554
RM2451
RM2620
RM2454
DM2652
FOR YOUR SAFETY
If you smell gas:
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of
this or any other appliance.
I m p r o p e r i n s t a l l a t i o n , a d j u s t m e n t ,
alteration, service or maintenance can cause
injury or property damage. Refer to this man-
ual. For assistance or additional information
consult a qualified installer, service agency
or the gas supplier.
If the refrigerator stops cooling - or - if
it emits an ammonia smell, immediately
turn the refrigerator off and contact a
Service Center.
3313238.036
REVISION
Form No. 3313238.036 7/11
(Replaces 3313238.028)
(French 3313239.034)
©2011 Dometic, LLC
LaGrange, IN 46761
DM2662
DM2862
DM2663
RM3962
RM3762
NDM1062
RM2820
RM1350
DM2852
NDA1402
USA
Dometic, LLC
Service Office
2320 Industrial Pkwy.
Elkhart, IN 46516
Phone: 574-294-2511
INSTALLATION
INSTRUCTIONS
PAR MESURE DE SÉCURITÉ
Si on détecte une odeur de gaz :
1. Ouvrir les fenêtres.
2. Ne pas toucher les commutateurs
électriques.
3. Éteindre toute flamme nue.
4. Contacter immédiatement le fournisseur
de gaz.
PAR MESURE DE SÉCURITÉ
Ne pas entreposer ou utiliser de l'essence
ou autre vapeur ou liquide inflammable au
voisinage de cet appareil ou de tout autre
appareil ménager.
AVERTISSEMENT
!
Une installation, un réglage, une modification,
un dépannage ou un entretien effectués
incorrectement, peuvent provoquer des
blessures ou des dommages matériels.
Se reporter à ce manuel. Pour obtenir une
aide ou des informations complémentaires,
consulter
un
installateur
entreprise de dépannage ou le fournisseur
de gaz.
AVERTISSEMENT
!
Si le réfrigérateur cesse de refroidir - ou - s'il
s'en dégage une odeur d'ammoniac, arrêter
immédiatement le réfrigérateur et contacter
un centre de service après-vente.
CANADA
Dometic, LLC
48 Zatonski, Unit 3
Brantford, ON N3T 5L8
CANADA
Phone: 519-720-9578
qualifié,
une
Corporate Office
2320 Industrial Parkway
Elkhart, IN 46516
For Service Center
Assistance
Call: 800-544-4881

Advertisement

Table of Contents
loading

Summary of Contents for Dometic RM2351

  • Page 1 Elkhart, IN 46516 48 Zatonski, Unit 3 Service Office (Replaces 3313238.028) For Service Center Brantford, ON N3T 5L8 2320 Industrial Pkwy. (French 3313239.034) CANADA Assistance Elkhart, IN 46516 ©2011 Dometic, LLC Phone: 519-720-9578 Call: 800-544-4881 Phone: 574-294-2511 LaGrange, IN 46761...
  • Page 2 NOTES - 2 -...
  • Page 3: Table Of Contents

    CONTENTS CERTIFICATION AND CODE REQUIREMENTS ................4 INSTALLATION PREPARATION ......................5 VENT APPLICATION TYPES ......................8 INSTALLATION PROCEDURE ......................13 REFRIGERATOR REMOVAL ......................27 APPENDIX A - OVERALL & ROUGH IN DIMENSIONS FOR ENCLOSURE ........28 APPENDIX B - MINIMUM VENTILATION HEIGHTS ................ 29 APPENDIX C - APPROVED VENTS ....................
  • Page 4: Certification And Code Requirements

    • Can reduce cooling performance and/or result in Dometic, LLC. damage to the refrigerator. • Will void agency certifications. • Will void refrigerator warranty.
  • Page 5: Installation Preparation

    INSTALLATION PREPARATION ASSEMBLING THE - OEM installed components inside of the refrigerator enclosure are contained outside of the ventiliation com- REFRIGERATOR ENCLOSURE partment by means of permanently securing them (e.g. behind paneling, behind batt-type insulation, inside of paneled storage space above refrigerator) in such a man- ner that OEM installed components will not come into The ventilation compartment is part of the product contact with the refrigerator.
  • Page 6: Ventilation Requirements

    “OFFSET VENTS”, page 8. - Any insulation used must be securely attached to the • Safety certification requires specified Dometic vents, see enclosure walls and ceiling in order to prevent it from “APPENDIX C” shifting when the refrigerator is installed in enclosure.
  • Page 7 INSTALLATION PREPARATION • The flow of combustion and ventilating air must not be If there is more than 1” between the inside of the ventila- obstructed, e.g. by an open RV door. tion compartment and cooling unit, it is required to add box baffle(s) starting above the lower access vent and running per- •...
  • Page 8: Vent Application Types

    For offset vent applications, prior written approval and safety certification must be obtained from Dometic, LLC. FIG 8 - OFFSET VENT FIG 9 - OFFSET VENT...
  • Page 9 VENT APPLICATION TYPES ROOF VENT APPLICATION INSTALL ROOF VENT • O 1 - t INSTALL LOWER SIDE VENT AND ROOF VENT ptiOn ypical “APPENDIX D” Step Action CHECK VENTILATION HEIGHT. “APPENDIX B” Minimum Ventilation Height RECESS DEPTH • O 2 - i ptiOn nbOard Inboard installs due to radius roof or interference with building material.
  • Page 10 VENT APPLICATION TYPES UPPER AND LOWER SIDE VENT ISLAND APPLICATION APPLICATION ACCESS PANEL INSTALL UPPER AND LOWER SIDE VENTS • A sealed access panel is required when using this system in conjunction with below floor ventilation. Step Action Access is necessary to complete gas connections, gas leak tests, and periodic service requirements at the rear of the CHECK VENTILATION HEIGHT.
  • Page 11 VENT APPLICATION TYPES ISLAND APPLICATION CONT'D INSTALL ACCESS PANEL INSTALL DUCT AND ROOF VENT INSTALL DUCT Step Action CHECK VENTILATION HEIGHT. INSTALL ROOF VENT “APPENDIX B” “APPENDIX D” CORNER APPLICATION OPTION 1 - INSTALL LOWER SIDE VENT AND ROOF VENT Step Action CHECK VENTILATION HEIGHT.
  • Page 12 VENT APPLICATION TYPES INSTALL LOWER SIDE VENT. CHECK RECESS DEPTH. See “INSTALLATION PREPARATION > RE- “APPENDIX D” CESS DEPTH”. A box baffle is required above the lower access vent. INSTALL ROOF VENT “APPENDIX D” Roof vent opening must be a mini- mum of 110 in unobstructed free area.
  • Page 13: Installation Procedure

    FIG 11. Be careful not to damage the sealing strip when the refrigerator is put in place! FIG 11 - RM2351, RM2354, RM2410 & RM2510 Apply sealing strip along floor here. Sealing...
  • Page 14 INSTALLATION PROCEDURE RM2410 & RM2510 RM2620 & RM2820 Install the six screws in the following order: Install the screws in the following order: 1. Two screws installed through the front base. 1. Two screws installed through the front base. 2. Two screws installed in the top frame. 2.
  • Page 15 INSTALLATION PROCEDURE RM2451, RM2454, RM2551, RM2554, b) Secure the refrigerator and the lower front strip with two screws. DM2652, DM2662, DM2663, DM2852, DM2862, RM3762, RM3962, RM1350, NDA1402 & NDM1062 Install the screws in the following order: 1. TWO SCREWS INSTALLED THROUGH THE FRONT BASE.
  • Page 16: Drain Water Hose

    INSTALLATION PROCEDURE 2. TWO SCREWS INSTALLED IN THE TOP 3. ONE SCREW INSTALLED IN THE REAR BASE. FRAME. OPTIONAL SCREW MAY BE ADDED. RM2451, RM2454, RM2551, RM2554, DM2652, RM2451, RM2454, RM2551, RM2554, DM2652, DM2662, DM2663, DM2852, DM2862 & NDM1062 DM2662, DM2663, DM2852, DM2862, RM3762, RM3962 &...
  • Page 17 INSTALLATION PROCEDURE OPTION 2 - THROUGH VENT FRAME (PLASTIC ELECTRICAL CONNECTION VENTS ONLY) 120 VAC CONNECTION Pull end of hose through louvers in vent door. Cut hose The refrigerator is equipped with a grounded three-prong plug to length. Reinstall perforated plug. for protection against shock hazards.
  • Page 18 Ignition switch MAXIMUM WIRE LENGTH WIRE Size Length Charge light MODEL Alternator signal wire to the refrigerator RM2351, RM2451 RM2551, DM2652 DM2662, DM2852 DM2862, RM3762 Battery RM3962, NDM1062 RM1350, NDA1402 ALTERNATOR RM2354, RM2454 RM2554, DM2663 Example: If the distance between the refrigerator and the 12 VDC supply is 20 ft., the total wire length is 40 ft.
  • Page 19 FIG 19 - RM2410 & RM2510, REVERSING THE DOOR SWING INSTRUCTIONS REVERSING THE DOOR SWING RM2351, RM2354, RM2451, RM2454, DM2652, DM2662, DM2663, RM2551, RM2554, RM3762, DM2852, DM2862, RM3962, NDM1062 & NDA1402 A special hinge kit must be used in order to change the door swing.
  • Page 20 4. Unscrew the bottom hinge pin. DOOR PANEL DIMENSIONS 5. Remove the plastic cap from the opposite lower RM2351, RM2354, RM2410, RM2451, RM2454, RM2510, hinge and place it in the hole just “left empty” by RM2620, DM2652, DM2662, DM2663, RM2551, RM2554, the lower hinge pin.
  • Page 21 INSTALLATION PROCEDURE DOOR PANEL DIMENSIONS CONT'D NDA1402 RM1350 Freezer door Refrigerator doo MODELS EQUIPPED WITH ICE MAKER PANEL DIMENSIONS FIG 21 - PANEL DIMENSIONS FOR THE FREEZER DOOR MAX. THICKNESS 5/32" HEIGHT WIDTH .197(2x) (5)(2x) .197 (2x) (5)(2x) UPPER DOOR RM1350M RM1350MIM 19-7/32 19-9/64 15-43/64 15-19/32...
  • Page 22: Refrigerator Door

    INSTALLATION PROCEDURE DOOR PANEL DIMENSIONS CONT'D NDA1402 MODELS EQUIPPED WITH ICE DISPENSER / ICE & WATER DIS- Freezer door Refrigerator door PENSERS Freezer door Refrigerator door Freezer door Refrigerator door FIG 23 - PANEL DIMENSIONS FOR THE FREEZER DOOR FIG 24 - PANEL DIMENSIONS FOR THE FRIDGE DOOR .197(2x) (5)(2x) .197 (2x) (5)(2x) .197(2x) (5)(2x)
  • Page 23 To install the door panel, follow these steps: MOUNTING INSTRUCTIONS 1. Open the door 90 degrees. RM2351, RM2354, RM2451, RM2454, DM2652, DM2662, DM2663, RM2551, RM2554, DM2852, DM2862 & NDM1062 2. Locate decoration strips. On some refrigerators, the decoration strip is taped inside the door; if installed...
  • Page 24 INSTALLATION PROCEDURE DOOR PANEL INSTALLATION CONT'D 5. Snap on the handle. RM3762 & RM3962 To install the door panels, follow these steps: 1. Remove the decoration strip by inserting a finger in the plastic profile and pull. REPLACING THE DOOR PANELS To replace a mounted door panel, follow these steps: 1.
  • Page 25 INSTALLATION PROCEDURE 5. Put back the decoration strip. Slide (A) or DOOR PANEL INSTALLATION CONT'D snap (B) into place. RM1350 To install the door panels, follow these steps: 1. Open the door. 2. Remove the screw (A). Slide off the handle (B).* * For RM1350WID it is not necessary to remove the right freezer door handle in order to mount the door panel.
  • Page 26 INSTALLATION PROCEDURE DOOR PANEL INSTALLATION CONT'D NDA1402 MODELS EQUIPPED WITH ICE MAKER Freezer door NDA1402 Freezer door MODELS EQUIPPED WITH ICE DISPENSER / ICE & WATER DISPENSERS Refrigerator door Refrigerator door - 26 -...
  • Page 27: Refrigerator Removal

    INSTALLATION PROCEDURE INSTALLING THE DOOR HANDLES NDM1062 To install the door handles, follow these steps: RM3762 & RM3962 - Stainless steel doors To install the door handles, follow these steps: 1. Locate the plastic bag containing the handles and screws. 1.
  • Page 28: Appendix A - Overall & Rough In Dimensions For Enclosure

    APPENDIX A - OVERALL & ROUGH IN DIMENSIONS FOR ENCLOSURE OVERALL DIMENSIONS ENCLOSURE DIMENSIONS MODEL Height (A) Width (B) Depth (C) Height (H) Width (W) Depth (D) RM2351 30-5/32 21-7/8 22-22/32 29-3/4 20-1/2 21-1/2 RM2354 30-5/32 21-7/8 22-22/32 29-3/4 20-1/2...
  • Page 29: Appendix B - Minimum Ventilation Heights

    APPENDIX B - MINIMUM VENTILATION HEIGHTS MINIMUM VENTILATION HEIGHTS ROOF VENT & LOWER SIDE VENT B1 = ROOF VENT & LOWER SIDE VENT B2 = UPPER & LOWER SIDE VENT RM2351 RM2354 RM2410 37-3/4 RM2451 37-3/4 RM2454 Minimum RM2510 Ventilation...
  • Page 30: Appendix C - Approved Vents

    31-33. Start by locating the refrigerator model in question, e.g. RM2351 and then, select vent application type. In this case, numbers 1 and 2 indicate that Roof Vent (1) and Side Vent (2) could be installed. As another exam- ple, when selecting model DM2652 with an upper and lower side vent application, use Upper Side Vent (2) and Lower Side Vent (2).
  • Page 31 APPENDIX C - APPROVED VENTS PLASTIC ROOF VENT UPPER & LOWER PLASTIC SIDE VENT Part No 3311236.xxx* Part No 3109350.xxx* Cutout: 6-1/2” x 23-3/4” Cutout: 13-3/4” x 21-9/16” UPPER METAL SIDE VENT UPPER METAL SIDE VENT Part No 3100451.xxx* Part No 8030122.xxx* Cutout: 7-3/4”...
  • Page 32 APPENDIX C - APPROVED VENTS LOWER METAL SIDE VENT UPPER & LOWER PLASTIC SIDE-BY-SIDE VENT Part No 3102364.xxx* Part No 3109349.xxx* Part No 8030211.xxx* Cutout: 9-11/16” x 19-1/4” Cutout: 13-5/8” x 28-5/8” UPPER & LOWER PLASTIC SIDE VENT Part No 3109492.xxx* Cutout: 9-11/16”...
  • Page 33 APPENDIX C - APPROVED VENTS CONT'D (INNOVATOR REFRIGERATOR (INNOVATOR REFRIGERATOR VENTILATION SYSTEM*) VENTILATION SYSTEM*) Part No 3108705.751 Part No 3108705.744 Patent #5,355,693 Z-BRACKET Wall or Frame Wall or Frame "D" "D" "Z" Bracket "Z" Bracket "Z" Bracket 3103812. Use appropriate "D" Vent Vent XXX = 016 = .62"...
  • Page 34: Appendix D - Vent Installation Procedures

    APPENDIX D - VENT INSTALLATION PROCEDURES Reference “ ” for Approved Vents. APPENDIX C All fasteners referenced herein are to be provided by the installer. The screw types selected should be appropriate for the application for which they are being used. For example; wood screw thread type for wood engagement, self tap- ping screw thread type for metal engagement, and plastic screw thread type for plastic engagement.
  • Page 35: Appendix E - Rearview Equipment

    APPENDIX E - REARVIEW EQUIPMENT RM2351 & RM2354 1 heater - RM2351 2 heaters - RM2354 Relay Flue baffle Drain water hose Power module cover Protection cover Screw for protection cover Burner jet 12 V DC Manual gas shutoff valve...
  • Page 36 APPENDIX E - REARVIEW EQUIPMENT RM2451, RM2454, RM2551 & RM2554 Heater Relay, 3-way only Flue baffle Power module cover Protection cover 12V DC Screw for protection cover Burner jet 12 volt Terminal block Manual gas shutoff valve Inlet fitting Flexible cord Drain water hose RM2620 &...
  • Page 37 APPENDIX E - REARVIEW EQUIPMENT DM2652, DM2662, DM2663, DM2852, DM2862 & NDM1062 Heater(s) Relay, 3-Way only Thermofuse Flue baffle Power module cover Protection cover 12V DC Screw for protection cover 12 volt DC Terminal block Burner jet Drain water hose Manual gas Flexible cord shutoff valve...
  • Page 38 APPENDIX E - REARVIEW EQUIPMENT RM1350M Heaters Drain Water Hose Protection Plate 385 13 31−01 F4 (5A) F3 (5A) SWITCHED AC HTR AC HTR LAMP LINE NEUT TEST LINE NEUT 12V DC Flexible Cord Power Module Terminal Block, 12V DC LP - Gas Connection RM1350IM, RM1350MIM &...
  • Page 39 APPENDIX E - REARVIEW EQUIPMENT RM1350WID Water Hose Heating Cable Icemaker Drain Water Hose Water Hose Water Dispenser Door Control Unit Heaters Flexible Cord Ice Dispenser Protection Plate W A R N I N G ! D I S C O N N E C T 1 2 0 V A C B E F O R E S E R V I C I N G PART No.
  • Page 40 APPENDIX E - REARVIEW EQUIPMENT NDA1402 (WITH ICE DISPENSER) Heaters Flexible Cord Refrigerator 12V DC Burner Control Ice Dispenser Power Switch Protection Cover Power Module and Fuses Flue Baffle 12V DC Thermofuse Burner Jet Drain Water Hose Manual Gas Shut Off Valve Heating Cable Inlet Fitting Water Hose (Icemaker)
  • Page 41 APPENDIX E - REARVIEW EQUIPMENT NDM1062 (WITH ICE MAKER) Heater Relay Thermofuse Power Flue Baffle Module Cover Protection Cover 12V DC Flexible Cord Manual Gas Shutoff Valve Burner Jet Thermostat Flexible Cord Inlet Fitting 12V DC (Icemaker) Terminal Block Drain Water Hose Shown without Secondary Burner Housing for illustrative purposes only.
  • Page 42: Appendix F - Wiring Diagrams

    APPENDIX F - WIRING DIAGRAMS RM2351, RM2451 & RM2551 RM2354, RM2454 & RM2554 - 42 -...
  • Page 43 APPENDIX F - WIRING DIAGRAMS RM2410 385 13 76 120 VOLTS AC 120 VOLTS AC SWITCH THERMOSTAT JUNCTION BLOCK HEATER WHITE BLACK GREEN RM2510 293 00 92 2 100/120 VOLTS AC 12 VOLTS DC 12 VOLTS DC 100/120 VOLTS AC SWITCH THERMOSTAT JUNCTION BLOCK...
  • Page 44 APPENDIX F - WIRING DIAGRAMS RM2620 & RM2820 3 8 5 1 4 8 1 G R E E N P 1 − 1 P 3 − 4 O R A N G E P 1 − 4 P 3 − 3 B L U E P 1 −...
  • Page 45 APPENDIX F - WIRING DIAGRAMS DM2652, DM2852 & DM2862 (WITH OPTIONAL FAN) 3 8 5 1 4 8 4 G R E E N P 1 − 1 O R A N G E P 3 − 4 P 1 − 4 P 3 −...
  • Page 46 APPENDIX F - WIRING DIAGRAMS RM3762 & RM3962 3 8 5 1 4 9 5 C I R C U I T B O A R D P O W E R B R O W N P 1 − 1 B L A C K P 1 −...
  • Page 47 APPENDIX F - WIRING DIAGRAMS NDM1062 (STAINLESS STEEL DOORS & ICE MAKER) 3 8 5 1 4 4 4 G R E E N P 1 − 1 O R A N G E P 3 − 4 P 1 − 4 P 3 −...
  • Page 48 APPENDIX F - WIRING DIAGRAMS NDM1062 (DOOR INSERT PANELS) 3 8 5 1 4 0 5 G R E E N P 1 − 1 P 3 − 4 O R A N G E P 1 − 4 P 3 − 3 B L U E P 1 −...
  • Page 49 APPENDIX F - WIRING DIAGRAMS RM1350M (MANUAL DOOR LOCK & DOOR INSERT PANELS OR STEEL DOORS) 3 8 5 1 4 9 0 C I R C U I T B O A R D P O W E R B R O W N P 1 −...
  • Page 50 APPENDIX F - WIRING DIAGRAMS RM1350IM (AUTOMATIC DOOR LOCK, ICE MAKER & STEEL DOORS) 3 8 5 1 4 9 2 C I R C U I T B O A R D P O W E R B R O W N P 1 −...
  • Page 51 APPENDIX F - WIRING DIAGRAMS RM1350WID (AUTOMATIC DOOR LOCK, ICE MAKER, WATER AND ICE DISPENSERS & DOOR INSERT PANELS OR STEEL DOORS) 3 8 5 1 4 9 4 C I R C U I T B O A R D P O W E R B R O W N P 1 −...
  • Page 52 APPENDIX F - WIRING DIAGRAMS NDA1402* 3 8 5 1 3 2 4 C I R C U I T B O A R D P O W E R E L E C T R O D E C I R C U I T B O A R D D I S P L A Y S O L E N O I D V A L V E 1 2 V D C B U R N E R C O N T R O L T H E R M O S T A T...
  • Page 53 APPENDIX F - WIRING DIAGRAMS NDA1402 (WITH ICE DISPENSER) 3851324 (2) + 3850897(3) NDA1402 (WITH ICE AND WATER DISPENSERS) 3851324 (2) + 3851112 - 53 -...

Table of Contents